dc.description.abstractPurpose: The aim of this study was to evaluate the microleakage of 4 fiber post-luting systems using the computerized fluid filtration method. Methods: 60 extracted human mandibular permanent premolar teeth were used for the study. The teeth were instrumented with Hedstroem files up to size 60, post spaces were prepared and then Unicore fiber posts were cemented using 4 luting systems. Group1: Duolink, Group 2: Resinomer, Group 3: Fuji Plus, Group 4: Multilink Sprint, Group 5: Positive Control, and Group 6: Negative Control. The samples were stored in distilled water for 2 weeks and then microleakage was evaluated. Data were analyzed with 1 way-ANOVA and Dunett T3 tests (P<.05). Groups 2 and 3 significantly exhibited higher microleakage values than groups 1 and 4 (P<.05). Results: Resin cements used with total etch-bonding systems demonstrated lower microleakage values than the other cements. Conclusions: Reduction of steps in dentin conditioning of resin luting cements may have a promoting effect on microleakage.en_US
dc.identifier.doi10.5301/ijao.5000459
dc.identifier.endpage650en_US
dc.identifier.issn0391-3988
dc.identifier.issn1724-6040
dc.identifier.issue12en_US
dc.identifier.pmid26847498en_US
dc.identifier.scopus2-s2.0-84957885601en_US
dc.identifier.scopusqualityQ3en_US
dc.identifier.startpage646en_US
dc.identifier.urihttps://doi.org/10.5301/ijao.5000459
dc.identifier.urihttps://hdl.handle.net/20.500.12491/8121
dc.identifier.volume38en_US
dc.identifier.wosWOS:000371790500004en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorOruçoğlu, Hasan
dc.language.isoenen_US
dc.publisherSage Publications Ltd.en_US
dc.relation.ispartofInternational Journal Of Artificial Organsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectFiber Posten_US
dc.subjectLuting Cementen_US
dc.subjectMicroleakageen_US
dc.titleMicroleakage of 4 post-luting cements evaluated by the computerized fluid filtration methoden_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
kadir-t.-ceyhanli.pdf
Boyut:
228.09 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam metin/Full text