Microleakage of 4 post-luting cements evaluated by the computerized fluid filtration method
dc.authorid | 0000-0002-9336-2865 | |
dc.authorid | 0000-0002-7701-5329 | |
dc.authorid | 0000-0003-1914-6491 | |
dc.authorid | 0000-0001-7405-1677 | |
dc.contributor.author | Ceyhanlı, Kadir Tolga | |
dc.contributor.author | Oruçoğlu, Hasan | |
dc.contributor.author | Erdilek, Necdet | |
dc.contributor.author | Türkün, Murat | |
dc.contributor.author | Akdağ, Mustafa S. | |
dc.date.accessioned | 2021-06-23T19:37:11Z | |
dc.date.available | 2021-06-23T19:37:11Z | |
dc.date.issued | 2015 | |
dc.department | BAİBÜ, Diş Hekimliği Fakültesi, Endodonti Ana Bilim Dalı | en_US |
dc.description.abstract | Purpose: The aim of this study was to evaluate the microleakage of 4 fiber post-luting systems using the computerized fluid filtration method. Methods: 60 extracted human mandibular permanent premolar teeth were used for the study. The teeth were instrumented with Hedstroem files up to size 60, post spaces were prepared and then Unicore fiber posts were cemented using 4 luting systems. Group1: Duolink, Group 2: Resinomer, Group 3: Fuji Plus, Group 4: Multilink Sprint, Group 5: Positive Control, and Group 6: Negative Control. The samples were stored in distilled water for 2 weeks and then microleakage was evaluated. Data were analyzed with 1 way-ANOVA and Dunett T3 tests (P<.05). Groups 2 and 3 significantly exhibited higher microleakage values than groups 1 and 4 (P<.05). Results: Resin cements used with total etch-bonding systems demonstrated lower microleakage values than the other cements. Conclusions: Reduction of steps in dentin conditioning of resin luting cements may have a promoting effect on microleakage. | en_US |
dc.identifier.doi | 10.5301/ijao.5000459 | |
dc.identifier.endpage | 650 | en_US |
dc.identifier.issn | 0391-3988 | |
dc.identifier.issn | 1724-6040 | |
dc.identifier.issue | 12 | en_US |
dc.identifier.pmid | 26847498 | en_US |
dc.identifier.scopus | 2-s2.0-84957885601 | en_US |
dc.identifier.scopusquality | Q3 | en_US |
dc.identifier.startpage | 646 | en_US |
dc.identifier.uri | https://doi.org/10.5301/ijao.5000459 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12491/8121 | |
dc.identifier.volume | 38 | en_US |
dc.identifier.wos | WOS:000371790500004 | en_US |
dc.identifier.wosquality | Q3 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.institutionauthor | Oruçoğlu, Hasan | |
dc.language.iso | en | en_US |
dc.publisher | Sage Publications Ltd. | en_US |
dc.relation.ispartof | International Journal Of Artificial Organs | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Fiber Post | en_US |
dc.subject | Luting Cement | en_US |
dc.subject | Microleakage | en_US |
dc.title | Microleakage of 4 post-luting cements evaluated by the computerized fluid filtration method | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Küçük Resim Yok
- İsim:
- kadir-t.-ceyhanli.pdf
- Boyut:
- 228.09 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam metin/Full text