The relationship of high-frequency distortion product otoacoustic emission (DPOAE) values with hematological parameters in tinnitus patients

dc.authorid0000-0002-8164-4056en_US
dc.authorid0000-0002-4253-919Xen_US
dc.authorid0000-0001-9554-8922
dc.authorid0000-0002-3840-8402
dc.authorid0000-0002-6088-1415
dc.contributor.authorGüneş, Akif
dc.contributor.authorKaralı, Elif
dc.contributor.authorUral, Ahmet
dc.contributor.authorRüzgar, Fatih
dc.contributor.authorBayatkara, Tuğba
dc.date.accessioned2021-06-23T19:50:39Z
dc.date.available2021-06-23T19:50:39Z
dc.date.issued2019
dc.departmentBAİBÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümüen_US
dc.description.abstractPurpose In this study, we aimed to investigate whether there is any positive or negative correlation between high-frequency distortion product otoacoustic emission (DPOAE) values and mean platelet volume (MPV) and neutrophil/lymphocyte ratio (NLR) in tinnitus patients. Methods The study was performed with 52 volunteers (27 females, 25 males) aged between 35 and 50 years who presented with tinnitus to the otolaryngology outpatient clinic of a tertiary care center. Pure voice audiometric examination, DPOAE measurement, complete blood count values of the study participants were examined. Results In both ears, a significant and negative correlation was observed between 4000 and 8000 Hz airway and 4000 Hz bone conduction pathways with NLR rates (p < 0.05). A statistically significant relationship was found between the bone conduction pathway PTA and discrimination values for both ears and NLR s (p < 0.05). A positive correlation was detected between NLRs and DPOAE measurements recorded at 4444 Hz, 5000 Hz, 8000 Hz, 8889 Hz, 10,000 Hz and 11,429 Hz frequencies in the right and 4444 Hz, 5000 Hz, 6154 Hz, 8000 Hz, 10,000 Hz and 11,429 Hz frequencies in the left ears, respectively (p < 0.05). Conclusions We concluded that there is a significant correlation between high-frequency pure tone audiometry measurements and high frequency DPOAE measurements and NLR. Further studies are needed to determine the utility of NLR as a marker for the recognition and follow-up of hearing loss in patients with tinnitus.en_US
dc.identifier.doi10.1007/s00405-019-05585-4
dc.identifier.endpage3019en_US
dc.identifier.issn0937-4477
dc.identifier.issn1434-4726
dc.identifier.issue11en_US
dc.identifier.pmid31372714en_US
dc.identifier.scopus2-s2.0-85070111352en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage3013en_US
dc.identifier.urihttps://doi.org/10.1007/s00405-019-05585-4
dc.identifier.urihttps://hdl.handle.net/20.500.12491/9833
dc.identifier.volume276en_US
dc.identifier.wosWOS:000492037800007en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorGüneş, Akif
dc.institutionauthorKaralı, Elif
dc.institutionauthorUral, Ahmet
dc.institutionauthorRüzgar, Fatih
dc.institutionauthorBayatkara, Tuğba
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.relation.ispartofEuropean Archives Of Oto-Rhino-Laryngologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectTinnitusen_US
dc.subjectAuto-Acoustic Emissionen_US
dc.subjectDPOAEen_US
dc.subjectNeutrophilen_US
dc.subjectlymphocyte Ratioen_US
dc.titleThe relationship of high-frequency distortion product otoacoustic emission (DPOAE) values with hematological parameters in tinnitus patientsen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
akif-gunes.pdf
Boyut:
469.41 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin/Full Text