Simple approach to the repeatability of the schirmer test without anesthesia - Eyes open or closed?

dc.authorid0000-0002-9719-9604
dc.authorid0000-0002-7614-5690
dc.contributor.authorSerin, Didem
dc.contributor.authorKarslıoğlu, Şafak
dc.contributor.authorKıyan, Aysu
dc.contributor.authorAlagöz, Gürsoy
dc.date.accessioned2021-06-23T19:19:54Z
dc.date.available2021-06-23T19:19:54Z
dc.date.issued2007
dc.departmentBAİBÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümüen_US
dc.description.abstractPurpose: To compare the repeatability of the Schirmer test (ST) administered with the eyes open (STo) with the repeatability of the ST administered with the eyes closed (STc). Methods: STo and STc without anesthesia were alternately applied with 1-day intervals for a total of 6 times on 28 eyes of 14 healthy volunteers. The intraclass correlation coefficients (ICCs) and their 95% confidence intervals(Cls) were calculated to assess test-retest reliability of the STo and STc. Results: STc scores were found to be statistically lower than the STo scores in general (right eyes: t = 2.033, P = 0.048; left eyes: t = 3.474, P = 0.004). The ICC was 0.632 (right eyes) and 0.618 (left eyes) for STo and 0.943 (right eyes) and 0.933 (left eyes) for STc. Conclusions: Our study suggests that administering the ST with the patient's eves closed produces less variable results and more repeatability than STo in normal Subjects. Although our results may not extend to dry eye patient populations, we propose that STc without anesthesia can be considered by those ophthalmologists who frequently use the ST as an adjunct to the differential diagnosis of dry eye in patients presenting with Ocular discomfort, making ST a more reliable test in everyday practice.en_US
dc.identifier.doi10.1097/ICO.0b013e3180950083
dc.identifier.endpage906en_US
dc.identifier.issn0277-3740
dc.identifier.issue8en_US
dc.identifier.pmid17721285en_US
dc.identifier.scopus2-s2.0-34548291586en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage903en_US
dc.identifier.urihttps://doi.org/10.1097/ICO.0b013e3180950083
dc.identifier.urihttps://hdl.handle.net/20.500.12491/6025
dc.identifier.volume26en_US
dc.identifier.wosWOS:000249048300001en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorSerin, Didem
dc.institutionauthorKıyan, Aysu
dc.institutionauthorAlagöz, Gürsoy
dc.language.isoenen_US
dc.publisherLippincott Williams & Wilkinsen_US
dc.relation.ispartofCorneaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectSchirmer Testen_US
dc.subjectRepeatabilityen_US
dc.subjectDry Eyeen_US
dc.subjectAqueous Tear Productionen_US
dc.titleSimple approach to the repeatability of the schirmer test without anesthesia - Eyes open or closed?en_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
didem-serin.pdf
Boyut:
173.57 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam metin/Full text