Vacuum-assisted closure for skin necrosis after revision total knee arthroplasty

dc.authorid0000-0003-2221-4731en_US
dc.authorid0000-0001-9395-1881
dc.contributor.authorSarman, Hakan
dc.contributor.authorMüezzinoğlu, Ümit Sefa
dc.contributor.authorMemişoğlu, Kaya
dc.contributor.authorBaran, Tuncay
dc.date.accessioned2021-06-23T19:42:57Z
dc.date.available2021-06-23T19:42:57Z
dc.date.issued2016
dc.departmentBAİBÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümüen_US
dc.description.abstractAlthough skin necrosis following total knee arthroplasty or revision total knee arthroplasty is rare, it may cause severe complications. Skin changes begin with superficial infections and may result in removal of the prosthesis. Treatment of skin necrosis is an important factor, which determines the prognosis of the prosthesis. Several techniques have been defined for sufficient closure. In this article, we present the case of a patient who was treated for skin necrosis that developed after knee revision arthroplasty, using serial debridement, convergence sutures and an intermittent vacuum-assisted closure device (KCI Inc., San Antonio, TX).en_US
dc.identifier.doi10.1111/iwj.12390
dc.identifier.endpage847en_US
dc.identifier.issn1742-4801
dc.identifier.issn1742-481X
dc.identifier.issue5en_US
dc.identifier.pmid25597628en_US
dc.identifier.scopus2-s2.0-85023757215en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage843en_US
dc.identifier.urihttps://doi.org/10.1111/iwj.12390
dc.identifier.urihttps://hdl.handle.net/20.500.12491/8652
dc.identifier.volume13en_US
dc.identifier.wosWOS:000387667600090en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorSarman, Hakan
dc.language.isoenen_US
dc.publisherWileyen_US
dc.relation.ispartofInternational Wound Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectRevision total knee arthroplastyen_US
dc.subjectSkin Necrosisen_US
dc.subjectTherapyen_US
dc.subjectVacuum-Assisted Closureen_US
dc.titleVacuum-assisted closure for skin necrosis after revision total knee arthroplastyen_US
dc.typeArticleen_US

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
International Wound Journal - 2015 - Sarman - Vacuum‐assisted closure for skin necrosis after revision total knee.pdf
Size:
1.87 MB
Format:
Adobe Portable Document Format
Description:
Tam Metin/Full Text