Evaluation of the effects of different composite materials and surface roughening techniques in bonding attachments of clear aligner on monolithic zirconia

dc.authorid0000-0001-9241-8882en_US
dc.authorid0000-0001-8055-3470en_US
dc.contributor.authorArslan, Semiha
dc.contributor.authorKılınç, Hamiyet
dc.date.accessioned2023-11-23T06:08:11Z
dc.date.available2023-11-23T06:08:11Z
dc.date.issued2023en_US
dc.departmentBAİBÜ, Diş Hekimliği Fakültesi, Ortodonti Ana Bilim Dalıen_US
dc.description.abstractObjective: The aim of this study is to evaluate the bond strengths of two different composite types used in the production of clear aligner attachments on monolithic zirconia with three different surface roughening processes.Materials and Methods: Packable composite Filtek Z250 was used in one group (PC-G) and flowable composite Filtek Supreme Ultra Flowable was used in the other group (FC-G). PC-G and FC-G groups were also divided into three subgroups as diamond bur+silane (Group 1), 50 mu m aluminium oxide (Al2O3) sandblasting+silane (Group 2) and 110 mu m Al2O3 sandblasting+silane (Group 3). Scanning electron microscopy (SEM) analysis was performed. Clear aligner attachments were bonded to the monolithic zirconia specimens. Shear bond strength (SBS) values were measured. Statistical analysis was performed using two-way ANOVA and post-hoc Tukey's tests (P < .05).Results: The highest SBS value was found in PC-G sandblasted with 110 mu m Al2O3 (P <= .001). The etching method with 110 mu m sandblasting showed high SBS values in both composite types. The lowest SBS value gave FC-G in diamond bur roughening (P <= .001).Conclusions: For the bonding of clear aligner attachments on monolithic zirconia, roughening with 110 mu m particle size sandblasting and the choice of packable composite could be recommended in terms of retention.en_US
dc.identifier.citationArslan, S., & Kilinc, H. (2023). Evaluation of the effects of different composite materials and surface roughening techniques in bonding attachments of clear aligner on monolithic zirconia. Orthodontics & Craniofacial Research.en_US
dc.identifier.doi10.1111/ocr.12643
dc.identifier.endpage6en_US
dc.identifier.issn1601-6335
dc.identifier.issn1601-6343
dc.identifier.pmid36840412en_US
dc.identifier.scopus2-s2.0-85150424440en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage1en_US
dc.identifier.urihttp://dx.doi.org/10.1111/ocr.12643
dc.identifier.urihttps://hdl.handle.net/20.500.12491/11873
dc.identifier.wosWOS:000945981300001en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorKılınç, Hamiyet
dc.institutionauthorKılınç, Hamiyet
dc.language.isoenen_US
dc.publisherWileyen_US
dc.relation.ispartofOrthodontics and Craniofacial Researchen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectClear Aligneren_US
dc.subjectMonolithic Zirconiaen_US
dc.subjectRougheningen_US
dc.subjectMetal Bracketsen_US
dc.subjectStrengthen_US
dc.subjectProtocolen_US
dc.titleEvaluation of the effects of different composite materials and surface roughening techniques in bonding attachments of clear aligner on monolithic zirconiaen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
hamiyet-arslan.pdf
Boyut:
1.41 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin/Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: