Kirschner wire versus titanium elastic nails in pediatric femoral shaft fractures
dc.authorid | 0000-0003-2221-4731 | en_US |
dc.authorid | 0000-0002-9750-9350 | en_US |
dc.contributor.author | Işık, Cengiz | |
dc.contributor.author | Kurtulmuş, Tuhan | |
dc.contributor.author | Sağlam, Necdet | |
dc.contributor.author | Saka, Gürsel | |
dc.contributor.author | Akpınar, Fuat | |
dc.contributor.author | Sarman, Hakan | |
dc.date.accessioned | 2021-06-23T19:37:46Z | |
dc.date.available | 2021-06-23T19:37:46Z | |
dc.date.issued | 2015 | |
dc.department | BAİBÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü | en_US |
dc.description.abstract | Objective: To evaluate the effectiveness of intramedullary fixation using the Kirschner-wire (K-wire) compared to the titanium elastic nail (TEN) in pediatric femoral shaft fractures. Methods: A sample of 42 pediatric patients with a mean age of 6.55 +/- 2.42 years (range 4-11 years) presenting femoral shaft fractures underwent intramedullary fixation using the K-wire or TEN. Results: There was no significant difference found between groups, of which 16 (38.1%) patients were treated with K-wire and 26 (61.9%) patients were treated with TEN in terms of union duration. Moreover, none of the patients showed nonunion or a delayed union. Conclusions: The use of adjusted K-wire instead of TEN in the intramedullary fixation of femoral shaft fractures in selected children may be an advantageous surgical option due to the lower cost, easy accessibility and no need for a second surgery for implant removal. | en_US |
dc.identifier.doi | 10.1590/1413-785220152305145030 | |
dc.identifier.endpage | 258 | en_US |
dc.identifier.issn | 1413-7852 | |
dc.identifier.issn | 1809-4406 | |
dc.identifier.issue | 5 | en_US |
dc.identifier.pmid | 26981033 | en_US |
dc.identifier.scopus | 2-s2.0-84948780052 | en_US |
dc.identifier.scopusquality | Q3 | en_US |
dc.identifier.startpage | 255 | en_US |
dc.identifier.uri | https://doi.org/10.1590/1413-785220152305145030 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12491/8209 | |
dc.identifier.volume | 23 | en_US |
dc.identifier.wos | WOS:000363403600006 | en_US |
dc.identifier.wosquality | Q4 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.institutionauthor | Işık, Cengiz | |
dc.institutionauthor | Akpınar, Fuat | |
dc.institutionauthor | Sarman, Hakan | |
dc.language.iso | en | en_US |
dc.publisher | Atha Comunicacao & Editora | en_US |
dc.relation.ispartof | Acta Ortopedica Brasileira | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Child | en_US |
dc.subject | Bone Nails | en_US |
dc.subject | Femoral Fractures | en_US |
dc.subject | Humeral Fractures | en_US |
dc.subject | Fracture Fixation, Intramedullary | en_US |
dc.subject | Titanium | en_US |
dc.title | Kirschner wire versus titanium elastic nails in pediatric femoral shaft fractures | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- cengiz-isik.pdf
- Boyut:
- 275.72 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam metin/Full text