Evaluation of the effects of Er:YAG laser, Nd:YAG laser, and two different desensitizers on dentin permeability: in vitro study

dc.authorid0000-0001-5939-8170en_US
dc.authorid0000-0002-3711-6520en_US
dc.authorid0000-0003-1330-3927
dc.authorid0000-0002-9336-2865
dc.contributor.authorKurt, Sevda
dc.contributor.authorKırtıloğlu, Tuğrul
dc.contributor.authorYılmaz, Nasibe Aycan
dc.contributor.authorErtaş, Ertan
dc.contributor.authorOruçoğlu, Hasan
dc.date.accessioned2021-06-23T19:49:22Z
dc.date.available2021-06-23T19:49:22Z
dc.date.issued2018
dc.departmentBAİBÜ, Diş Hekimliği Fakültesi, Endodonti Ana Bilim Dalıen_US
dc.description.abstractThe purpose of this in vitro study was to evaluate and compare the efficacy of erbium-doped yttrium aluminum garnet (Er:YAG) laser, neodymium-doped yttrium aluminum garnet (Nd:YAG) laser, PrevDent nano-hydroxyapatite toothpaste plus Repairing Serum Kit (PNH), and NUPRO Sensodyne Prophylaxis Paste with NovaMin (NPP) on dentin permeability reduction. Forty dentin discs obtained from bovine incisors were divided into four study groups: Er:YAG laser-treated (2940nm; 0.2W, 80mJ/pulse, 3Hz); Nd:YAG laser-treated (1064nm; 1W, 10Hz); PNH-treated; and NPP-treated groups. The quantitative changes in permeability of each dentin disc were measured using a computerized fluid filtration method (CFFM) before and after desensitizer treatments. The data were analyzed using the Wilcoxon, paired-samples t, Kruskal-Wallis, and Mann-Whitney U tests. The dentin surfaces and tubules were also morphologically detected by scanning electron microscopy (SEM). In all groups, dentin permeability was significantly reduced after the desensitizer and laser treatments (p<0.05). Among the groups, we detected a significant difference in only when comparing the Er:YAG laser- and NPP-treated groups (p=0.034). SEM analysis revealed physical changes in the dentin surface in all groups. This in vitro study shows that all tested desensitizers and laser treatments reduced dentin permeability. Also, surface changes, such as complete or partial occlusion or shrinkage of dentin tubules, were observed in all groups. Although the laser groups performed best, the PNH protocol can be considered as an alternative therapeutic product. In addition, clinical and laboratory studies should be performed for this product, and their efficacy should be assessed by combined therapy with lasers.en_US
dc.identifier.doi10.1007/s10103-018-2546-1
dc.identifier.endpage1890en_US
dc.identifier.issn0268-8921
dc.identifier.issn1435-604X
dc.identifier.issue9en_US
dc.identifier.pmid29850962en_US
dc.identifier.scopus2-s2.0-85047823526en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage1883en_US
dc.identifier.urihttps://doi.org/10.1007/s10103-018-2546-1
dc.identifier.urihttps://hdl.handle.net/20.500.12491/9479
dc.identifier.volume33en_US
dc.identifier.wosWOS:000450033200006en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorOruçoğlu, Hasan
dc.language.isoenen_US
dc.publisherSpringer London Ltden_US
dc.relation.ispartofLasers In Medical Scienceen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectDentin Sensitivityen_US
dc.subjectDentin Permeabilityen_US
dc.subjectComputerized Fluid Filtration Deviceen_US
dc.subjectLaseren_US
dc.titleEvaluation of the effects of Er:YAG laser, Nd:YAG laser, and two different desensitizers on dentin permeability: in vitro studyen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
sevda-kurt.pdf
Boyut:
3.07 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin/Full Text