The right ventricle systolic force ratio could predictthe severity of the tricuspid regurgitation-RIVIERA ratio

dc.authorid0000-0001-6595-7493en_US
dc.authorid0000-0002-6913-9073en_US
dc.authorid0000-0002-6724-1445en_US
dc.authorid0000-0002-0465-8454en_US
dc.authorid0000-0001-7742-7107en_US
dc.authorid0000-0003-3817-851Xen_US
dc.contributor.authorAcar, Emrah
dc.contributor.authorİzci, Servet
dc.contributor.authorDönmez, İbrahim
dc.contributor.authorYılmaz, Mehmet Fatih
dc.contributor.authorÖzgül, Neryan
dc.contributor.authorSeymen, Hande
dc.contributor.authorÖzcan, Eda
dc.contributor.authorGüneş, Yılmaz
dc.date.accessioned2023-08-29T10:51:39Z
dc.date.available2023-08-29T10:51:39Z
dc.date.issued2023en_US
dc.departmentBAİBÜ, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümüen_US
dc.description.abstractPurpose: For assessing the severity of tricuspid regurgitation (TR), there is no gold standard. We developed a parameter, the right ventricular systolic force ratio-RIVIERA, using the continious wave Doppler analysis of TR and pulsed-wave analysis of the right ventricle outflow tract. We hypothesized that the RIVIERA would facilitate the ability to identify severe TR in clinical settings.Materials and Methods: We obtained data from routine transthoracic echocardiograms. All records reporting no or mild TR (n = 732), moderate TR (n = 584), and severe TR (n = 519) TR were reanalyzed to measure vena contracta (VC) width, TR jet area, effective regurgitant orifice (EROA) derived with the proximal isovelocity surface area method, the RIVIERA, and right-sided chamber volumes.Results: Significant linear trends were demonstrated for right atrial volume index, end-diastolic volume index, RVOT velocity time integral, TR jet area, TR-Vmax, TR-VTI, TR acceleration, VC width, EROA with increasing TR severity. Independent predictors of severe RT included RIVIERA <4.8, VC width =0.7 cm, TR jet area > 10 cm(2), and EROA =0.4 cm(2).Conclusion: The RIVIERA is a feasible, effective, and independent predictor of severe TR that enhances established techniques for estimating TR severity. For clinical decision-making and management, accurate measurement and classification of TR severity are essential. Therefore, it should be thought about include the RIVIERA in the integrative method to assessing TR severity.en_US
dc.identifier.citationEmrah, A., Servet, I., Ibrahim, D., Fatih, Y. M., Neryan, O., Hande, S., ... & Cevat, K. (2023). The right ventricle systolic force ratio could predict the severity of the tricuspid regurgitation‐RIVIERA ratio. Journal of Clinical Ultrasound.en_US
dc.identifier.doi10.1002/jcu.23457
dc.identifier.endpage9en_US
dc.identifier.issn0091-2751
dc.identifier.issn1097-0096
dc.identifier.pmid37000708en_US
dc.identifier.scopus2-s2.0-85152028181en_US
dc.identifier.scopusqualityQ3en_US
dc.identifier.startpage1en_US
dc.identifier.urihttp://dx.doi.org/10.1002/jcu.23457
dc.identifier.urihttps://hdl.handle.net/20.500.12491/11618
dc.identifier.wosWOS:000962183900001en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorAcar, Emrah
dc.institutionauthorDönmez, İbrahim
dc.institutionauthorSeymen, Hande
dc.institutionauthorÖzcan, Eda
dc.institutionauthorGüneş, Yılmaz
dc.language.isoenen_US
dc.publisherWileyen_US
dc.relation.ispartofJournal of Clinical Ultrasounden_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAccelerationen_US
dc.subjectDoppleren_US
dc.subjectForceen_US
dc.subjectRight Ventricle Outflow Tracten_US
dc.subjectTricuspid Regurgitationen_US
dc.subjectVelocity-Time Integralen_US
dc.titleThe right ventricle systolic force ratio could predictthe severity of the tricuspid regurgitation-RIVIERA ratioen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
emrah-acar.pdf
Boyut:
2.3 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin/Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: