Polymerization capacity of orthodontic composites analyzed by Fourier transform infrared spectroscopy

dc.authorid0000-0002-7802-4251
dc.contributor.authorÇörekçi, Bayram
dc.contributor.authorMalkoç, Sıddık
dc.contributor.authorÖztürk, Bora
dc.contributor.authorGündüz, Beniz
dc.contributor.authorToy, Ebubekir
dc.date.accessioned2021-06-23T19:28:12Z
dc.date.available2021-06-23T19:28:12Z
dc.date.issued2011
dc.departmentBAİBÜ, Diş Hekimliği Fakültesi, Ortodonti Ana Bilim Dalıen_US
dc.description.abstractIntroduction: The aim of this in-vitro study was to analyze the polymerization capacity of 5 orthodontic composites by determining the degree of monomer conversion (DC). Methods: Fourier transform infrared spectroscopy was used to evaluate the DC of the orthodontic composites immediately after polymerization and after storage in artificial saliva at 37 degrees C +/- 1 degrees C for 30 days. The resin-based adhesive composites investigated were Bisco Ortho (Bisco, Schaumburg, III), Heliosit Orthodontics (Ivoclar, Schaan, Liechtenstein), Kurasper F (Kuraray, Okayama, Japan), Light Bond (Reliance Orthodontic Products, Itasca, III), and Transbond XT (3M Unitek, Monrovia, Calif), cured with Elipar FreeLight 2 (3M ESPE, St Paul, Minn) for the testing of the DC values. Fifty cylindrical specimens were manufactured in molds. The data were analyzed by 2-factor analysis of variance (ANOVA) and Tukey HSD test. Results: According to 2-way ANOVA, the DC was significantly influenced by composite type (P < 0.05); after 30 days, there were no differences among the composite types for the DC. The interaction of orthodontic composites and time played a statistically significant role in the DC (P < 0.05), but there was no statistically significant influence of time for the DC (P > 0.05). Conclusions: The DC was found to change according to composite materials used, and Bisco Ortho showed the most DC performance. The DC of orthodontic composites is a complex process that is affected not only by inorganic filler content of the composite but also the monomer type and many other factors. Sufficient DC values of 5 commercially available orthodontic composites can be achieved with a new-generation light-emitting diode curing light. (Am J Orthod Dentofacial Orthop 2011;139:e299-e304)en_US
dc.identifier.doi10.1016/j.ajodo.2009.05.033
dc.identifier.endpageE304en_US
dc.identifier.issn0889-5406
dc.identifier.issue4en_US
dc.identifier.pmid21457835en_US
dc.identifier.scopus2-s2.0-79953316057en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpageE299en_US
dc.identifier.urihttps://doi.org/10.1016/j.ajodo.2009.05.033
dc.identifier.urihttps://hdl.handle.net/20.500.12491/6972
dc.identifier.volume139en_US
dc.identifier.wosWOS:000288982500003en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorÇörekçi, Bayram
dc.language.isoenen_US
dc.publisherMosby-Elsevieren_US
dc.relation.ispartofAmerican Journal Of Orthodontics And Dentofacial Orthopedicsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectOrthodontic Compositesen_US
dc.titlePolymerization capacity of orthodontic composites analyzed by Fourier transform infrared spectroscopyen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
bayram-corekci.pdf
Boyut:
236.57 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam metin / Full Text