Validation of one-step cleanup and separation method of polychlorinated biphenyls, organochlorine pesticides, and polycyclic aromatic hydrocarbons from atmospheric gas- and particle-phase samples

dc.authorid0000-0003-3182-9340en_US
dc.authorid0000-0002-0107-0110
dc.contributor.authorKarakaş, Serpil Yenisoy
dc.contributor.authorGaga, Eftade O.
dc.date.accessioned2021-06-23T19:34:11Z
dc.date.available2021-06-23T19:34:11Z
dc.date.issued2013
dc.departmentBAİBÜ, Fen Edebiyat Fakültesi, Kimya Bölümüen_US
dc.description.abstractA one-step cleanup method is described for the determination of PAHs, PCBs and OCPs in air (gas and particulate phase) samples. Analytes were extracted from ambient air samples using soxhlet extraction with a solvent mixture of dichloromethane and petroleum ether (1:4) for 24 h. They were concentrated, separated and fractionated on a florisil and alumina column. The amounts of florisil (1 g or 2 g) with/ without alumina were tested in the cleanup column. The study systematically investigated the effects of solvent types, and the amounts of florisil and alumina, on the performance of the cleanup process. The first fraction was eluted with 25 mL hexane, and analyzed for PCBs. The second fraction was collected via 40 mL hexane ethyl acetate (1:1) solvent mixture, and analyzed for OCPs and PAHs. The optimized method yielded average recoveries between 88% and 99% for PCBs; 56% and 118% for PAHs; and 51% and 128% for OCPs. Other validation parameters were also investigated, such as MDL, LOQ linear range, sensitivity (r(2)). An oven-program optimization and adjustment of GC-MS were performed. For internal quality control, surrogate recoveries and field blanks values were calculated. External calibration curves were prepared for PAHs, and internal calibration curves were preferred for OCP and PCBs. (c) 2013 Elsevier B.V. All rights reserved.en_US
dc.identifier.doi10.1016/j.talanta.2013.04.049
dc.identifier.endpage158en_US
dc.identifier.issn0039-9140
dc.identifier.issn1873-3573
dc.identifier.pmid24054572en_US
dc.identifier.scopus2-s2.0-84878104119en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage150en_US
dc.identifier.urihttps://doi.org/10.1016/j.talanta.2013.04.049
dc.identifier.urihttps://hdl.handle.net/20.500.12491/7417
dc.identifier.volume115en_US
dc.identifier.wosWOS:000328095600019en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorKarakaş, Serpil Yenisoy
dc.language.isoenen_US
dc.publisherElsevier Science Bven_US
dc.relation.ispartofTalantaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAir Samplesen_US
dc.subjectCleanupen_US
dc.subjectMethod Validationen_US
dc.subjectPolycyclic Aromatic Hydrocarbonsen_US
dc.subjectPolychlorinated Biphenylsen_US
dc.subjectOrganochlorine Pesticidesen_US
dc.titleValidation of one-step cleanup and separation method of polychlorinated biphenyls, organochlorine pesticides, and polycyclic aromatic hydrocarbons from atmospheric gas- and particle-phase samplesen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
serpil-yenisoy-karakas.pdf
Boyut:
1.04 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam metin/Full text