New needle holder facilitates percutaneous fluoroscopy-guided sacroiliac puncture
dc.contributor.author | Uğur, Fatih | |
dc.contributor.author | Gülcü, Nebahat | |
dc.date.accessioned | 2021-06-23T19:19:05Z | |
dc.date.available | 2021-06-23T19:19:05Z | |
dc.date.issued | 2006 | |
dc.department | BAİBÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü | en_US |
dc.description | 39th Congress of the Turkish-Society-of- Anesthesiology-and-Reanimation -- OCT, 2005 -- Antalya, TURKEY | en_US |
dc.description.abstract | Purpose: To evaluate the success of a new guidance device for sacroiliac joint puncture. Material and Methods: The device was first tested on a human anatomical model and thereafter on two groups of patients. In the first group (n = 8), the traditional hand-guided method was used, and in the second group (n = 10) the needle-holder device. The parameters evaluated in each group were "the number of attempts'', defined as the number of skin punctures, and "fluoroscopy-injection time'', defined as the time from the beginning of the fluoroscopy to the end of the correct insertion of the needle into the joint. Results: Sacroiliac injection with the new device required significantly fewer attempts (2.1 +/- 2 versus 4.3 +/- 3) and shorter fluoroscopy injection times (8.9 +/- 3 min versus 15 +/- 5 min; P < 0.05). Conclusion: The new guidance device makes sacroiliac joint injection easier and prevents unnecessary exposure to radiation during the procedure. | en_US |
dc.description.sponsorship | Turkish Soc Anesthesiol & Reanimat | en_US |
dc.identifier.doi | 10.1080/02841850600634890 | |
dc.identifier.endpage | 483 | en_US |
dc.identifier.issn | 0284-1851 | |
dc.identifier.issue | 5 | en_US |
dc.identifier.pmid | 16796310 | en_US |
dc.identifier.startpage | 481 | en_US |
dc.identifier.uri | https://doi.org/10.1080/02841850600634890 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12491/5869 | |
dc.identifier.volume | 47 | en_US |
dc.identifier.wos | WOS:000238247600008 | en_US |
dc.identifier.wosquality | Q4 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.institutionauthor | Gülcü, Nebahat | |
dc.language.iso | en | en_US |
dc.publisher | Taylor & Francis Ltd | en_US |
dc.relation.ispartof | Acta Radiologica | en_US |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Fluoroscopy | en_US |
dc.subject | Joints | en_US |
dc.subject | Percutaneous Injection | en_US |
dc.title | New needle holder facilitates percutaneous fluoroscopy-guided sacroiliac puncture | en_US |
dc.type | Conference Object | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Küçük Resim Yok
- İsim:
- fatih-ugur.pdf
- Boyut:
- 190.83 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam metin/ Full text