Comparison of apical microleakage of dual-curing resin cements with fluid-filtration and dye extraction techniques
dc.authorid | 0000-0001-6089-3013 | en_US |
dc.authorid | 0000-0002-9336-2865 | en_US |
dc.contributor.author | Kaya, Sadullah | |
dc.contributor.author | Özer, Senem Yiğit | |
dc.contributor.author | Adigüzel, Özkan | |
dc.contributor.author | Oruçoğlu, Hasan | |
dc.contributor.author | Değer, Yalçın | |
dc.date.accessioned | 2021-06-23T19:42:12Z | |
dc.date.available | 2021-06-23T19:42:12Z | |
dc.date.issued | 2015 | |
dc.department | BAİBÜ, Diş Hekimliği Fakültesi, Endodonti Ana Bilim Dalı | en_US |
dc.description.abstract | Background: Endodontically treated teeth with excessive loss of tooth structure are frequently restored using fiber posts. In this in vitro study, the apical leakage of self-and dual-activated curing modes for dual-curing resins cementing a translucent fiber post was evaluated using computerized fluid filtration meter and dye extraction method. Material/Methods: One hundred and four extracted human maxillary incisors with single root and canal were used. Experimental samples embedded in a closed system were divided into 4 groups (n=20) according to 2 dual-curing luting systems, with 2 different curing modes (either with self-or light-activation): (1) Panavia F 2.0 with self-cure, (2) Panavia F 2.0 with light-activation, (3) Clearfill SA with self-cure, and (4) Clearfill SA with light activation. Twenty-four teeth served as negative and positive controls. Translucent fiber posts were luted in the roots except in the control groups. Results: Statistical analysis indicated no significant difference in leakage among groups (p>0.05) with 4.12x10(-4) (Panavia self-cure), 4.55x10(-4) (Clearfill SA self-cure), 5.17x10(-4) (Panavia dual-cure), and 5.59x10(-4) (Clearfill SA dual-cure) in fluid-filtration method. Absorbance values for dye-extraction method were 266 nanometer (nm) (Panavia self-cure), 268 nm (Clearfill SA self-cure), 270 nm (Panavia dual-cure), and 271 nm (Clearfill SA dual-cure), in which difference among the groups were not statistically significant (p>0.05). When comparing the leakage, assessment methods results showed no statistically significant difference between the tested evaluation techniques (p>0.05). Conclusions: Light-and self-activation curing modes of Panavia F 2.0 and Clearfill SA perform similar to each other in a closed system. | en_US |
dc.identifier.issn | 1643-3750 | |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.uri | https://hdl.handle.net/20.500.12491/8392 | |
dc.identifier.uri | https://www.medscimonit.com/abstract/index/idArt/892741/s/B | |
dc.identifier.volume | 21 | en_US |
dc.identifier.wos | WOS:000352368300001 | en_US |
dc.identifier.wosquality | Q3 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.institutionauthor | Oruçoğlu, Hasan | |
dc.language.iso | en | en_US |
dc.publisher | Int Scientific Literature, Inc | en_US |
dc.relation.ispartof | Medical Science Monitor | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Curing Lights, Dental | en_US |
dc.subject | Dental Leakage | en_US |
dc.subject | Endodontics | en_US |
dc.subject | Numerical Analysis, Computer-Assisted | en_US |
dc.subject | Self-Curing of Dental Resins | en_US |
dc.subject | Tooth, Nonvital | en_US |
dc.title | Comparison of apical microleakage of dual-curing resin cements with fluid-filtration and dye extraction techniques | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Küçük Resim Yok
- İsim:
- sadullah-kaya.pdf
- Boyut:
- 256.92 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam metin/Full text