Effect of a 50-Hz sinusoidal electromagnetic field on the integrity of experimental colonic anastomoses covered with fibrin glue
dc.authorid | 0000-0002-2435-7800 | en_US |
dc.authorid | 0000-0002-4889-7473 | |
dc.authorid | 0000-0001-5608-5742 | |
dc.authorid | 0000-0002-2435-7800 | |
dc.authorid | 0000-0003-1218-4962 | |
dc.contributor.author | Girgin, Sadullah | |
dc.contributor.author | Öztürk, Hayrettin | |
dc.contributor.author | Gedik, Ercan | |
dc.contributor.author | Akpolat, Veysi | |
dc.contributor.author | Kale, Ebru | |
dc.contributor.author | Öztürk, Hülya | |
dc.date.accessioned | 2021-06-23T19:26:26Z | |
dc.date.available | 2021-06-23T19:26:26Z | |
dc.date.issued | 2009 | |
dc.department | BAİBÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü | en_US |
dc.description.abstract | Background. Low-frequency magnetic fields have been shown to affect biological processes. In this article the effects of 50-Hz sinusoidal magnetic field (MF) stimulation and application of fibrin glue on the healing of experimental colonic anastomoses were investigated. Material and Methods. Twenty-eight rats were divided into four groups. Group 1 underwent 2-cm left colonic resection and primary anastomosis. Group 2 underwent normal resection anastomosis and the area was covered with fibrin glue. Group 3 underwent normal resection anastomosis and the rats were exposed to a 50-Hz sinusoidal MF. Group 4 underwent normal resection anastomosis, the anastomosis area was covered with fibrin glue, and the rats were exposed to a 50-Hz sinusoidal MF. Investigations included bursting pressure measurement, hydroxyproline content, and histopathological changes. Results. Tissue hydroxyproline levels and anastomotic bursting pressures of groups 2, 3, and 4 were significantly higher than in group 1. Collagen deposition and fibroblast infiltration in groups 2, 3, and 4 had higher scores than in group 1. Furthermore, these results were significantly higher in group 4 rats than in the other groups. Histopathological examination of the anastomosis revealed significantly better healing patterns for group 4 than for groups 1, 2, and 3. Conclusions. A50-Hz sinusoidal MF stimulation and application of fibrin glue provided a significant gain in anastomotic healing in the large intestine. A combination of a 50-Hz sinusoidal MF and fibrin glue has significantly favorable effects on healing of experimental colon anastomosis (Adv Clin Exp Med 2009, 18, 1, 13-18). | en_US |
dc.identifier.endpage | 18 | en_US |
dc.identifier.issn | 1899-5276 | |
dc.identifier.issn | 2451-2680 | |
dc.identifier.issue | 1 | en_US |
dc.identifier.scopus | 2-s2.0-64249112625 | en_US |
dc.identifier.scopusquality | Q1 | en_US |
dc.identifier.startpage | 13 | en_US |
dc.identifier.uri | https://hdl.handle.net/20.500.12491/6547 | |
dc.identifier.uri | https://advances.umw.edu.pl/pdf/2009/18/1/13.pdf | |
dc.identifier.volume | 18 | en_US |
dc.identifier.wos | WOS:000270038600002 | en_US |
dc.identifier.wosquality | Q4 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.institutionauthor | Öztürk, Hayrettin | |
dc.language.iso | en | en_US |
dc.publisher | Wroclaw Medical Univ | en_US |
dc.relation.ispartof | Advances In Clinical And Experimental Medicine | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Colonic Anastomosis | en_US |
dc.subject | 50-Hz Sinusoidal Magnetic Field | en_US |
dc.subject | Fibrin Glue | en_US |
dc.title | Effect of a 50-Hz sinusoidal electromagnetic field on the integrity of experimental colonic anastomoses covered with fibrin glue | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Küçük Resim Yok
- İsim:
- sadullah-girgin.pdf
- Boyut:
- 81.39 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam metin/Full text