A novel adaptable isometric strength analysis and exercise development system design

dc.authorid0000-0003-2181-070Xen_US
dc.authorid0000-0003-1851-8951en_US
dc.authorid0000-0001-5614-9021en_US
dc.contributor.authorFidan, Murat
dc.contributor.authorBayrak, Alper
dc.contributor.authorKarlı, Ümid
dc.date.accessioned2023-05-26T07:23:56Z
dc.date.available2023-05-26T07:23:56Z
dc.date.issued2021en_US
dc.departmentBAİBÜ, Mühendislik Fakültesi, Elektrik Elektronik Mühendisliği Bölümüen_US
dc.description.abstractIn this study, a low-cost and adaptable isometric strength measurement and exercise development system are described. The implemented system consists of mechanical structure, force measurement sensor, electronic circuit, and computer software. Isometric-isotonic (via spring resistance) strength analysis and various exercise programs can be applied with the system. The developed system has a lower cost compared to its counterparts in the literature and has a structure that can be adapted to different machines and measuring methods. The operability and reliability of the isometric strength measurement and exercise development system have been proven by calibration tests.en_US
dc.identifier.citationFidan, M., Bayrak, A., & Karli, U. (2021). A novel adaptable isometric strength analysis and exercise development system design. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 235(8), 913-926.en_US
dc.identifier.doi10.1177/09544119211015562
dc.identifier.endpage926en_US
dc.identifier.issn0954-4119
dc.identifier.issn2041-3033
dc.identifier.issue8en_US
dc.identifier.pmid33971770en_US
dc.identifier.scopus2-s2.0-85105716513en_US
dc.identifier.scopusqualityQ3en_US
dc.identifier.startpage913en_US
dc.identifier.urihttp://dx.doi.org/10.1177/09544119211015562
dc.identifier.urihttps://hdl.handle.net/20.500.12491/10966
dc.identifier.volume235en_US
dc.identifier.wosWOS:000652304700001en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorFidan, Murat
dc.institutionauthorBayrak, Alper
dc.institutionauthorKarlı, Ümid
dc.language.isoenen_US
dc.publisherSage Publications Ltden_US
dc.relation.ispartofProceedings of the Institution of Mechanical Engineers Part H-Journal of Engineering in Medicineen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectComputer-Aided Measurementen_US
dc.subjectMuscle Strengthen_US
dc.subjectAdaptable Systemen_US
dc.subjectIsometric Contractionen_US
dc.subjectIsotonic Contractionen_US
dc.titleA novel adaptable isometric strength analysis and exercise development system designen_US
dc.typeArticleen_US

Dosyalar

Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: