S-citalopram imprinted monolithic columns for capillary electrochromatography enantioseparations
dc.authorid | 0000-0003-3260-1639 | en_US |
dc.authorid | 0000-0001-7292-7241 | en_US |
dc.authorid | 0000-0001-7548-5741 | en_US |
dc.contributor.author | Derazshamshir, Ali | |
dc.contributor.author | Göktürk, Ilgım | |
dc.contributor.author | Yılmaz, Fatma | |
dc.contributor.author | Denizli, Adil | |
dc.date.accessioned | 2023-07-28T13:10:48Z | |
dc.date.available | 2023-07-28T13:10:48Z | |
dc.date.issued | 2021 | en_US |
dc.department | BAİBÜ, Gerede Meslek Yüksekokulu, Kimya ve Kimyasal İşleme Teknolojileri Bölümü | en_US |
dc.description | Bolu Abant Izzet Baysal University scientific project research foundation (BAP) | en_US |
dc.description.abstract | In this study, the molecular imprinting method was used to separate enantiomeric forms of chiral antidepressant drug, R,S-citalopram (R,S-CIT) in aqueous solution by CEC system combining the advantages of capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC). For that, an amino acid-based molecularly imprinted monolithic capillary column was designed and used as a stationary phase for selective separation of S-citalopram (S-CIT) for the first time. S-CIT was selectively separated from the aqueous solution containing the other enantiomeric form of R-CIT, which is the same in size and shape as the template molecule. Morphology of the molecularly imprinted (MIP S-CIT) and non-imprinted (NIP S-CIT) monolithic capillary columns was observed by scanning electron microscopy. Imprinting efficiency of MIP S-CIT monolithic capillary column used for selective S-CIT separation was verified by comparing with NIP S-CIT and calculated imprinting factor (I.F:1.81) proved the high selectivity of the MIP S-CIT for S-CIT. Cavities formed for S-CIT form enabled selective (alpha = 2.08) separation of the target molecule from the other enantiomeric R-CIT form. Separation was achieved in a short period of 10 min, with the electrophoretic mobility of 7.68 x 10(-6) m(2)/Vs for R,S-CIT at pH 7.0 10 mM PB and 50% ACN ratio. The performance of both MIP S-CIT and NIP S-CIT columns was estimated by repeating the R,S-CIT separations with intra-batch and inter-batch studies for reproducibility of retention times of R,S-CITs. Estimated RSD values that are lower than 2% suggest that the monolithic columns separate R,S-CIT enantiomers without losing separation efficiency. | en_US |
dc.description.sponsorship | Bolu Abant Izzet Baysal University scientific project research foundation (BAP) [2015.19.06.955]" | en_US |
dc.identifier.citation | Derazshamshir, A., Göktürk, I., Yılmaz, F., & Denizli, A. (2021). S‐citalopram imprinted monolithic columns for capillary electrochromatography enantioseparations. Electrophoresis, 42(24), 2672-2682. | en_US |
dc.identifier.doi | 10.1002/elps.202100222 | |
dc.identifier.endpage | 2682 | en_US |
dc.identifier.issn | 0173-0835 | |
dc.identifier.issn | 1522-2683 | |
dc.identifier.issue | 24 | en_US |
dc.identifier.pmid | 34406668 | en_US |
dc.identifier.scopus | 2-s2.0-85114661369 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.startpage | 2672 | en_US |
dc.identifier.uri | http://dx.doi.org/10.1002/elps.202100222 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12491/11399 | |
dc.identifier.volume | 42 | en_US |
dc.identifier.wos | WOS:000694986400001 | en_US |
dc.identifier.wosquality | Q2 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.institutionauthor | Yılmaz, Fatma | |
dc.language.iso | en | en_US |
dc.publisher | WILEY | en_US |
dc.relation.ispartof | Electrophoresis | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Antidepressant | en_US |
dc.subject | Capillary Electrochromatography | en_US |
dc.subject | Chirality | en_US |
dc.subject | Molecular Imprinting | en_US |
dc.subject | Monolithic Column | en_US |
dc.subject | Chiral Recognition | en_US |
dc.title | S-citalopram imprinted monolithic columns for capillary electrochromatography enantioseparations | en_US |
dc.type | Article | en_US |