Uncertainty of high resolution inductively coupled plasma mass spectrometry based aerosol measurements

dc.authorid0000-0002-1242-9360en_US
dc.authorid0000-0003-3182-9340en_US
dc.authorid0000-0002-0107-0110
dc.contributor.authorKarakaş, Serpil Yenisoy
dc.contributor.authorGaga, Eftade O.
dc.contributor.authorCankur, Oktay
dc.contributor.authorKarakaş, Duran
dc.date.accessioned2021-06-23T19:26:05Z
dc.date.available2021-06-23T19:26:05Z
dc.date.issued2009
dc.departmentBAİBÜ, Fen Edebiyat Fakültesi, Kimya Bölümüen_US
dc.description.abstractSimultaneous and multi-elemental method was optimized to determine 35 elements in 274 coarse and fine aerosol samples by using HR-ICP-MS. The procedures were validated. Measurement uncertainties of all elements including sampling uncertainties were calculated by applying bottom-up approach. The average recoveries obtained for each element ranged between 79% and 129% using NIST SRM 1648, urban dust. The calculated uncertainties of the analytical methods were between 2.9% and 18% for both sample types. The major contributions to the uncertainty budget come from the calibration curves, repeatability and volume of air. (C) 2009 Elsevier B.V. All rights reserved.en_US
dc.identifier.doi10.1016/j.talanta.2009.05.044
dc.identifier.endpage1305en_US
dc.identifier.issn0039-9140
dc.identifier.issue5en_US
dc.identifier.pmid19635363en_US
dc.identifier.scopus2-s2.0-67650991829en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage1298en_US
dc.identifier.urihttps://doi.org/10.1016/j.talanta.2009.05.044
dc.identifier.urihttps://hdl.handle.net/20.500.12491/6411
dc.identifier.volume79en_US
dc.identifier.wosWOS:000269288400019en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorKarakaş, Serpil Yenisoy
dc.language.isoenen_US
dc.publisherElsevier Science Bven_US
dc.relation.ispartofTalantaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectElementsen_US
dc.subjectAerosolsen_US
dc.subjectHigh Resolution Inductively Coupled Plasma Mass Spectrometryen_US
dc.subjectMethod Validationen_US
dc.subjectMicrowave Digestionen_US
dc.subjectUncertaintyen_US
dc.titleUncertainty of high resolution inductively coupled plasma mass spectrometry based aerosol measurementsen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
serpil-yenisoy-karakas.pdf
Boyut:
291.26 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam metin/Full text