International Nosocomial Infection Control Consortium (INICC) national report on device-associated infection rates in 19 cities of Turkey, data summary for 2003-2012

Yükleniyor...
Küçük Resim

Tarih

2014

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

BioMed Central Ltd.

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

Background: Device-associated healthcare-acquired infections (DA-HAI) pose a threat to patient safety, particularly in the intensive care unit (ICU). We report the results of the International Infection Control Consortium (INICC) study conducted in Turkey from August 2003 through October 2012. Methods: A DA-HAI surveillance study in 63 adult, paediatric ICUs and neonatal ICUs (NICUs) from 29 hospitals, in 19 cities using the methods and definitions of the U.S. NHSN and INICC methods. Results: We collected prospective data from 94,498 ICU patients for 647,316 bed days. Pooled DA-HAI rates for adult and paediatric ICUs were 11.1 central line-associated bloodstream infections (CLABSIs) per 1000 central line (CL)-days, 21.4 ventilator-associated pneumonias (VAPs) per 1000 mechanical ventilator (MV)-days and 7.5 catheter-associated urinary tract infections (CAUTIs) per 1000 urinary catheter-days. Pooled DA-HAI rates for NICUs were 30 CLABSIs per 1000 CL-days, and 15.8 VAPs per 1000 MV-days. Extra length of stay (LOS) in adult and paediatric ICUs was 19.4 for CLABSI, 8.7 for VAP and 10.1 for CAUTI. Extra LOS in NICUs was 13.1 for patients with CLABSI and 16.2 for patients with VAP. Extra crude mortality was 12% for CLABSI, 19.4% for VAP and 10.5% for CAUTI in ICUs, and 15.4% for CLABSI and 10.5% for VAP in NICUs. Pooled device use (DU) ratios for adult and paediatric ICUs were 0.54 for MV, 0.65 for CL and 0.88 for UC, and 0.12 for MV, and 0.09 for CL in NICUs. The CLABSI rate was 8.5 per 1,000 CL days in the Medical Surgical ICUs included in this study, which is higher than the INICC report rate of 4.9, and more than eight times higher than the NHSN rate of 0.9. Similarly, the VAP and CAUTI rates were higher compared with U.S. NHSN (22.3 vs. 1.1 for VAP; 7.9 vs. 1.2 for CAUTI) and with the INICC report (22.3 vs. 16.5 in VAP; 7.9 vs. 5.3 in CAUTI). Conclusions: DA-HAI rates and DU ratios in our ICUs were higher than those reported in the INICC global report and in the US NHSN report.

Açıklama

Anahtar Kelimeler

Antibiotic Resistance, Bloodstream Infection, Catheter-associated Urinary Tract Infection, Central Line-associated Bloodstream Infections, Device-associated Infection, Healthcare-associated Infection, Hospital Infection, INICC, International Nosocomial Infection Consortium, Network, Nosocomial Infection, Turkey, Urinary Tract Infection, Ventilator-associated Pneumonia

Kaynak

Annals of Clinical Microbiology and Antimicrobials

WoS Q Değeri

Scopus Q Değeri

Q1

Cilt

13

Sayı

1

Künye