Evaluation of Bio-Rad D-10® and arkray adams HA-8160® HPLC analyzers in HbA1c measurement
dc.authorid | 0000-0002-7006-3125 | |
dc.authorid | 0000-0002-4060-3354 | |
dc.authorid | 0000-0001-6878-0646 | |
dc.contributor.author | Yis, Özgür Mehmet | |
dc.contributor.author | Pehlivan, Mine Büşra | |
dc.contributor.author | Buğdaycı, Güler | |
dc.contributor.author | Yüce, Neslihan | |
dc.date.accessioned | 2021-06-23T18:34:12Z | |
dc.date.available | 2021-06-23T18:34:12Z | |
dc.date.issued | 2019 | |
dc.department | BAİBÜ, Tıp Fakültesi, Temel Tıp Bilimleri Bölümü | en_US |
dc.description.abstract | Glycosylated hemoglobin A1c (HbA1c) is an important parameter used for the assessment of time-dependent glycemic status and the diagnosis and follow-up of diabetes. This study aimed to evaluate the analytical performance of two HPLC analyzers, the Bio-Rad D-10®, and the Arkray Adams HA-8160®. Accuracy and imprecision studies were conducted, and a method comparison study was performed with 105 samples. Samples were collected on five consecutive days and measured on both analyzers within two hours. Bland-Altman and regression analyses were used for statistical evaluation of the data. Low and high-level within-day CV values were calculated as 1.22% and 0.60% for the Arkray analyzer and 1.2% and 0.30% for the Bio-Rad analyzer, respectively. They were calculated as 1.27% and 2.52% for the Arkray analyzer and 2.32% and 3.44% for the Bio-Rad analyzer, respectively, between days. The within-day CV values for both analyzers were below the limit of 2.5% specified by the International Federation of Clinical Chemistry (IFCC). The bias average for three months was 3.2% for the Arkray analyzer and 1.2% for the Bio-Rad analyzer. The Spearman correlation coefficient (r) was 0.973 (p<0.0001) between the two measurements, and the slope and intercept values calculated in the regression analyses showed the linear relationship and harmony between the two analyzers [R2 = 0.967, (y = 0.860x + 0.604)]. Both HPLC analyzers are shown to be reproducible and accurate for routine biochemistry laboratory use. | en_US |
dc.identifier.doi | 10.5455/medscience.2019.08.9084 | |
dc.identifier.endpage | 956 | en_US |
dc.identifier.issn | 2147-0634 | |
dc.identifier.issn | 2147-0634 | |
dc.identifier.issue | 4 | en_US |
dc.identifier.startpage | 953 | en_US |
dc.identifier.trdizinid | 379308 | en_US |
dc.identifier.uri | https://doi.org/10.5455/medscience.2019.08.9084 | |
dc.identifier.uri | https://app.trdizin.gov.tr/makale/TXpjNU16QTRPQT09 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12491/2433 | |
dc.identifier.volume | 8 | en_US |
dc.indekslendigikaynak | TR-Dizin | en_US |
dc.institutionauthor | Yis, Özgür Mehmet | |
dc.institutionauthor | Buğdaycı, Güler | |
dc.language.iso | en | en_US |
dc.relation.ispartof | Medicine Science | en_US |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Diabetes Mellitus | |
dc.subject | HbA1c | |
dc.subject | HPLC | |
dc.subject | Analytical Performance | |
dc.title | Evaluation of Bio-Rad D-10® and arkray adams HA-8160® HPLC analyzers in HbA1c measurement | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- ozgur-mehmet-yis.pdf
- Boyut:
- 505.45 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam metin/ Full text