Sağlıklı bireylerde optik koherens tomografi cihazının farklı çekim modlarıyla maküla kalınlığının değerlendirilmesi

dc.authorid0000-0003-4468-3985
dc.authorid0000-0002-3053-2396
dc.authorid0000-0003-1337-459X
dc.contributor.authorUlaş, Fatih
dc.contributor.authorSoydan, Adem
dc.contributor.authorBalbaba, Mehmet
dc.contributor.authorÇelebi, Serdal
dc.date.accessioned2021-06-23T18:35:37Z
dc.date.available2021-06-23T18:35:37Z
dc.date.issued2013
dc.departmentBAİBÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümüen_US
dc.description.abstractAmaç: Sağlıklı, genç bireylerde optik koherens tomografi (OKT) cihazının hızlı maküla kalınlığı ölçüm modu ve arka kutup analiz (PPA) ölçüm modu ile elde edilen maküla kalınlığı ölçüm sonuçlarının değerlendirilmesi. Gereç ve Yöntem: Bu geriye dönük çalışmaya Mart 2012-Ağustos 2012 tarihleri arasında göz polikliniğine başvuran, yaşları 20-30 arası değişen, daha önce geçirilmiş kronik bir göz hastalığı hikayesi olmayan 70 sağlıklı, genç birey dahil edildi. Hastaların 35'i (%50) erkek ve 35'i (%50) kadındı. Çalışmaya olguların sadece sağ gözlerinin maküla kalınlığı ve PPA ölçümleri dahil edildi. OKT cihazı ile hızlı maküla kalınlığı ve PPA ölçüm modlarının çekim ayarları değiştirilmeksizin rastgele sırayla ölçümler alındı. Ölçümler tek seansta, aynı deneyimli doktor tarafından ve pupil dilatasyonu uygulanmaksızın gerçekleştirildi. Hızlı maküla kalınlığı ve PPA modları ile alınan ölçümler arasındaki farkın istatistiksel analizi eşleştirilmiş örneklem t-testi ile yapıldı. Bu çekim modlarında alınan ölçümlerin uyumu sınıf içi korelasyon katsayısı (ICC), ölçüm sonuçlarının dağılımını belirlemek için varyasyon katsayısı (CV) değerleri hesaplandı. Bulgular: Hızlı maküla kalınlığı ve PPA modları ile alınan ölçümlerde değerlendirilen tüm segmentlerde ölçümler arasında fark saptanmadı (p değerleri 0.055 ile 0.571 arası). Her iki mod ile yapılan ölçümlerde, değerlendirilen tüm segmentlerin ICC değerleri 0.984 ile 0.992 aralığı gibi yüksek düzeylerde saptandı. CV değerleri ise hızlı maküla çekim ve PPA modlarında sırasıyla %4.40-5.79 ve %4.33-5.76 aralığı gibi oldukça düşük düzeylerdeydi. Sonuç: Sağlıklı, genç bireylerde, OKT cihazı kullanılarak yapılan farklı modlardaki maküla kalınlığı ölçüm sonuçlarının uyumu oldukça yüksektir.en_US
dc.description.abstractPurpose: To evaluate the measurements of macular thickness obtained by the fast macular thickness scanning mode and posterior pole analysis (PPA) mode in healthy, young subjects using optical coherence tomography (OCT). Materials and Methods: This prospective study was performed on 70 healthy, young subjects [35 (50%) males and 35 (50%) females] aged between 20 and 30 years who had no history of chronic eye disease and attended the ophthalmology outpatients between March 2012 and August 2012. Only the right eyes of the subjects were included to the study. Macular thickness measurements were performed with the default fast macular thickness scanning mode and PPA mode in random order. All OCT scans were performed by a single experienced physician without pupil dilation within one session. Statistical analyses of fast macular thickness scanning mode and PPA mode differences were performed using the paired samples t-test, the agreement of the measurements was analyzed using the intra-class correlation coefficient (ICC) and the dispersion of the measurements was analyzed using the coefficient of variation (CV). Results: There was no statistically significant difference between the fast macular thickness scanning mode and PPA mode measurements of all evaluated segments (p values ranged between 0.055 and 0.571). ICC values for these measurements were very high and ranged between 0.984 and 0.992. CV values for the fast macular thickness scanning mode and PPA mode measurements were quite low and ranged between 4.40-5.79% and 4.33-5.76%, respectively. Conclusion: The fast macular thickness scanning mode and PPA mode measurements using OCT have quite high agreement in healthy, young subjects.en_US
dc.identifier.endpage42en_US
dc.identifier.issn1300-1256
dc.identifier.issn2717-7149
dc.identifier.issue1en_US
dc.identifier.scopusqualityQ4en_US
dc.identifier.startpage38en_US
dc.identifier.trdizinid147917en_US
dc.identifier.urihttps://app.trdizin.gov.tr/makale/TVRRM09URTNOdz09
dc.identifier.urihttps://hdl.handle.net/20.500.12491/2713
dc.identifier.volume21en_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakTR-Dizinen_US
dc.institutionauthorUlaş, Fatih
dc.institutionauthorSoydan, Adem
dc.institutionauthorÇelebi, Serdal
dc.language.isotren_US
dc.relation.ispartofRetina-Vitreusen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectArka Kutup Analizien_US
dc.subjectMaküla Kalınlığı
dc.subjectOptik Koherens Tomografi
dc.subjectMacular Thickness
dc.subjectOptical Coherence Tomography
dc.subjectPosterior Pole Analysis
dc.titleSağlıklı bireylerde optik koherens tomografi cihazının farklı çekim modlarıyla maküla kalınlığının değerlendirilmesien_US
dc.title.alternativeEvaluation of macular thickness measurement in healthy subjects using different scanning modes of optical coherence tomographyen_US
dc.typeArticleen_US

Dosyalar