Umblikal kord morfometrisi ile fetal ve maternal parametreler arasındaki ilişkinin araştırılması

dc.authorid0000-0002-0334-1658
dc.authorid0000-0001-5672-0718
dc.contributor.authorKosif, Rengin
dc.contributor.authorBayar, Ülkü
dc.contributor.authorBaşaran, Mustafa
dc.contributor.authorGezer, Şener
dc.contributor.authorKaçar, Dündar
dc.contributor.authorKıyan, Aysu
dc.date.accessioned2021-06-23T18:43:20Z
dc.date.available2021-06-23T18:43:20Z
dc.date.issued2010
dc.departmentBAİBÜ, Tıp Fakültesi, Temel Tıp Bilimleri Bölümüen_US
dc.departmentBAİBÜ, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü
dc.description.abstractAmaç: Kordon çapı ve boyu ile fetal ve maternal parametreler arasındaki ilişkiyi postpartum dönemde incelemek. Materyal ve Metod: Zonguldak Karaelmas Üniversitesi Tıp Fakültesi Hastanesinde doğum yapmış 202 kadının maternal, plasental ve yenidoğana ait parametreleri, daha önceden hazırlanmış formlara doldurularak prospektif olarak incelendi. Bulgular: Maternal BMI ile kordon boyu arasında negatif korelasyon bulundu (p=0.045, r= -0.130). Umbilikal kord çapı yenidoğan boy, kilo, BMI ve göğüs çevresi ile pozitif korelasyon gösteriyordu. Umbilikal kord uzunluğu ile 5. dakika Apgar skoru arasında pozitif korelasyon vardı. Umbilikal kord uzunluğu plasenta santral kalınlığıyla pozitif korelasyon gösteriyordu. Umbilikal kord çapı tüm plasenta boyutları ve 5. dakika Apgar skoru ile pozitif korelasyon gösteriyordu. Umbilikal kord çapı ile uzunluğu arasında negatif korelasyon vardı (p=0.00, r=-0.227). Tüm istatistik sonuçları istatistiksel olarak anlamlı fakat zayıf korelasyon değerlerine sahiptir. Umbilikal kord morfolojisinin değerlendirilmesi önemlidir çünkü özellikle umbilikal kord çapındaki değişiklikler yenidoğan boyutlarını etkileyebilmektedir.en_US
dc.description.abstractAim: To research the relationship between diameter and length of umbilical cord and fetal and maternal parameters, with respect to postpartum period. Materials and Methods: Maternal, placental and neonatal parameters of202 women who delivered singleton delivery was filled to forms prepared previously and researched prospectively. Findings: Negative correlation was determined between maternal BMI and umbilical cord length (p=0.045, r= -0.130). Diameter of umbilical cord showed positive correlation with weight, lenght, BMI and chest circumference of newborn. Positive correlation between umbilical cord length and 5. minute Apgar score was found. Umbilical cord length showed positive correlation with placental central thickness. Umbilical cord diameter showed positive correlation with all dimensions of placenta and 5. minute Apgar score. There was a negative correlation between umbilical cord diameter and umbilical cord length (p=0.00, r= -0.227). All test scores showed statistically significant but weak correlations with umbilical cord length and diameter. Evaluating of the umbilical cord morphometry is important because of changes in umbilical cord diameter may especially affect outcome of newborn.en_US
dc.description.urihttps://dergipark.org.tr/tr/download/article-file/205499
dc.identifier.endpage135en_US
dc.identifier.issn1300-7971
dc.identifier.issn2148-4864
dc.identifier.issue3en_US
dc.identifier.startpage129en_US
dc.identifier.trdizinid123101en_US
dc.identifier.urihttps://app.trdizin.gov.tr/makale/TVRJek1UQXhNUT09
dc.identifier.urihttps://hdl.handle.net/20.500.12491/3775
dc.identifier.volume41en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.institutionauthorKosif, Rengin
dc.institutionauthorKıyan, Aysu
dc.language.isotren_US
dc.relation.ispartofZeynep Kamil Tıp Bültenien_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectUmblikal Kord Morfometrisien_US
dc.subjectCerebral Palsy
dc.subjectFetal
dc.subjectMaternal Parametre
dc.subjectInvestigation of the relationship
dc.subjectumbilical cord
dc.subjectmorphometry and fetal
dc.titleUmblikal kord morfometrisi ile fetal ve maternal parametreler arasındaki ilişkinin araştırılmasıen_US
dc.title.alternativeInvestigation of the relationship between umbilical cord morphometry and fetal and materyal parametersen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
rengin-kosif1.pdf
Boyut:
4.83 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam metin/ Full text