Energy cutoff effect in CORSIKA on the detected particles of pi pi(0) decay channel
Yükleniyor...
Tarih
2018
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Canadian Science Publishing, Nrc Research Press
Erişim Hakkı
info:eu-repo/semantics/openAccess
Özet
CORSIKA (COsmic Ray SImulations for Kascade) has various features in the creation of the extensive air showers with several characteristics where the users can configure the input card to achieve the desired result. ECUT is a parameter defined as the low energy cutoff of the particle kinetic energy for hadrons, muons, electrons, and photons. We investigate the effect of the different ECUT values on the detected particles in 10(7) - 5 x 10(8) GeV primary particle energy range where pi(-)pi(0) decay channel chosen with 5 km shower development length. The selected ECUT values in this study are 0.05 and 0.1 GeV for both hadrons and muons and 0.05 GeV for electrons and photons. The effect of the reducing by half on the energy cutoff value is studied for the detector array located on an inclined plane, which is planned for upward tau detection.
Açıklama
33rd International Physics Conference of Turkish-Physical-Society (TPS) -- SEP 06-10, 2017 -- Konacik, TURKEY
Anahtar Kelimeler
CORSIKA, UHECR, Array, Upward Showers, Pi Pi(0)