Plasma modified foley catheters against to catheter associated urinary tract infection (CAUTI)

dc.authorid0000-0001-9221-7706
dc.contributor.authorErdoğan, Gökhan
dc.contributor.authorDenktaş, Emir Baki
dc.contributor.authorÖztürk, Eylem
dc.contributor.authorAğalar, Canan
dc.contributor.authorEroğlu, Muzaffer
dc.date.accessioned2021-06-23T18:32:23Z
dc.date.available2021-06-23T18:32:23Z
dc.date.issued2008
dc.departmentBAİBÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümüen_US
dc.description.abstractIn this study; the foley catheters were modified by plasma polymerization technique and coated with alginate gels. This modification processes were applied to prevent bacterial adhesion onto the foley catheter surfaces. Here the most effective parameters were evaluated as the plasma polymerization system power and plasma exposure time for the effective catheter surface modification. The obtained results showed that the plasma power affected hidrophilicity of the surface and wettability of the foley catheters was increased. The plasma exposure time increased the amount of EDA deposition over the catheter surfaces and then caused more hydrophilicity for the foley catheter surfaces also. In this study, the bacterial strain of E. Coli had a hydrophobic nature and therefore the increase in hydrophilicity of the surface of foley catheters decreased the adhesion risk for the E. Coli onto the catheter surfaces. As the numerical values of the obtained data; while the amount of bacterial colony formation unit was at 108 level initially, it was decreased down to 104-103 level by changing the surface hydrophilicities as expected.en_US
dc.identifier.endpage8en_US
dc.identifier.issn1303-5002
dc.identifier.issn2687-475X
dc.identifier.issue1en_US
dc.identifier.startpage1en_US
dc.identifier.trdizinid76328en_US
dc.identifier.urihttps://app.trdizin.gov.tr/makale/TnpZek1qZzQ
dc.identifier.urihttps://hdl.handle.net/20.500.12491/1813
dc.identifier.volume36en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.institutionauthorEroğlu, Muzaffer
dc.language.isoenen_US
dc.relation.ispartofHacettepe Journal of Biology and Chemistryen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectFoley Catheter
dc.subjectPlasma Modification
dc.subjectAlginate
dc.subjectUrinary Tract Infection
dc.titlePlasma modified foley catheters against to catheter associated urinary tract infection (CAUTI)en_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
gokhan-erdogan.pdf
Boyut:
353.28 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam metin/ Full text