Glokomlu olgularda dört farklı tonometreyle ölçülen göz içi basınç ölçüm sonuçlarının karşılaştırılması ve merkezi kornea kalınlığı ile ilişkileri
dc.authorid | 0000-0003-1018-925X | |
dc.authorid | 0000-0001-8305-6600 | |
dc.authorid | 0000-0003-4468-3985 | |
dc.authorid | 0000-0002-8249-2621 | |
dc.contributor.author | Kaymaz, Abdulgani | |
dc.contributor.author | Çelebi, Serdal | |
dc.contributor.author | Ulaş, Fatih | |
dc.contributor.author | Doğan, Ümit | |
dc.date.accessioned | 2021-06-23T18:34:45Z | |
dc.date.available | 2021-06-23T18:34:45Z | |
dc.date.issued | 2014 | |
dc.department | BAİBÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü | en_US |
dc.description.abstract | Amaç: Glokomlu olgularda dört farklı tonometreyle ölçülen göz içi basınçlarının (GİB)karşılaştırılması ve merkezi kornea kalınlığı (MKK) ile ilişkilerinin araştırılması. Gereç ve Yöntem: Çalışmamızda glokom tanısı almış olguların Goldmann aplanasyon tonometresi (GAT), Tonopen tonometre (Tonopen Avia) ve nonkontakt tonometreler (NKT) (Canon TX-10 ve TX-20P) ile GİB ölçümleri ve ultrasonik pakimetre cihazı ile MKK ölçümleri yapıldı. Bulgular: Çalışmaya katılan 67 glokomlu olgunun yaş ortalaması 64,09±8,017 idi. Çalışmamızda Canon TX-10 ve TX-20P GİBstd (MKK'ye göre düzeltilmemiş Canon TX-20P GİB ölçümü) ile ölçülen GİB sonuçlarıyla MKK arasında istatistiksel olarak anlamlı orta düzeyde ilişki saptandı (sırasıyla TX-10 r=0,285, p=0,019, TX-20P GİBstd r=0,326, p=0,007). NKT TX-20P GİBcor (MKK'ye göre düzeltilmiş Canon TX-20P GİB ölçümü), Tonopen ve GAT ile ölçülen GİB değerleri ile MKK arasında istatistiksel olarak anlamlı ilişki saptanmadı (TX-20P GİBcor p=0,825, Tonopen p=0,980 ve GAT p=0,740). Canon TX-10 ve Tonopen ile ölçülen GİB değerleri GAT ile ölçülene göre hafif yüksek olmasına rağmen (sırasıyla 1,5 ve 1,8 mmHg) % 95’lik güven aralığı değerleri (sırasıyla 5,5 ve 5,6 mmHg) klinik olarak kabul edilemeyecek düzeylerdeydi. Canon TX-20P GİBstd ve TX-20P GİBcor değerleri GAT ile ölçülen GİB değerlerine göre klinik olarak kabul edilemeyecek düzeylerde yüksekti (sırasıyla 3 ve 3,5 mmHg). Sonuç: GAT, Canon TX-10, Canon TX-20P ve Tonopen ölçüm sonuçları birbirlerinin yerlerine kullanılmamalıdır. | en_US |
dc.description.abstract | Aim: To compare intraocular pressure measurements using four different tonometers and its relation with central corneal thickness in glaucoma patients. Material and Method: We measured IOP using Goldmann applanation tonometry (GAT), Tonopen tonometer (Tonopen Avia) and noncontact tonometer (NCT) (Canon TX-10 and TX-20P) and measured central corneal thickness (CCT) using ultrasonic pachymeter in glaucoma patients. Results: The study included 67 glaucoma patients with a mean age of 64.09±8.017. IOP values that were measured using NCT TX-10 and TX-20P IOPstd (IOP measurement of Canon TX-20P, which was not corrected according to central corneal thickness) had statistically moderate and significant correlation with CCT (respectively, TX-10 r=0.285, p=0.019, TX-20P IOPstd r=0.326 p=0.007). The IOP measurements of NCT TX-20P IOPcor (IOP measurement of Canon TX-20P, which was corrected according to central corneal thickness), Tonopen and GAT did not correlate significantly with CCT (TX-20P IOPcor p=0.825, Tonopen p=0.980 ve GAT p=0.740). Although IOP measurements of Canon TX-10 and Tonopen were slightly higher than GAT (1.5 mmHg and 1.8 mmHg, respectively), 95% confidence interval value had clinically unacceptable amplitude (5.5 mmHg and 5.6 mmHg, respectively). Canon TX-20PIOPstd and TX-20P IOPcor measurements were clinically unacceptably higher than GAT IOP measurements (3 mmHg and 3.5 mmHg, respectively). Conclusion: GAT, Canon TX-10, Canon TX-20P and Tonopen measurements should not be used interchangeably. | en_US |
dc.identifier.endpage | 252 | en_US |
dc.identifier.issn | 1300-4786 | |
dc.identifier.issue | 4 | en_US |
dc.identifier.startpage | 245 | en_US |
dc.identifier.trdizinid | 163774 | en_US |
dc.identifier.uri | https://app.trdizin.gov.tr/makale/TVRZek56YzBOQT09 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12491/2551 | |
dc.identifier.volume | 21 | en_US |
dc.indekslendigikaynak | TR-Dizin | en_US |
dc.institutionauthor | Kaymaz, Abdulgani | |
dc.institutionauthor | Çelebi, Serdal | |
dc.institutionauthor | Ulaş, Fatih | |
dc.institutionauthor | Doğan, Ümit | |
dc.language.iso | tr | en_US |
dc.relation.ispartof | MN Oftalmoloji | en_US |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Glokom | |
dc.subject | Goldmann Aplanasyon Tonometresi | |
dc.subject | Merkezi Kornea Kalınlığı | |
dc.subject | Nonkontakt Tonometre | |
dc.subject | Tonopen Tonometre | |
dc.subject | Glaucoma | |
dc.subject | Goldmann Applanation Tonometer | |
dc.subject | Central Corneal Thickness | |
dc.subject | Noncontact Tonometry | |
dc.subject | Tonopen Tonometer | |
dc.title | Glokomlu olgularda dört farklı tonometreyle ölçülen göz içi basınç ölçüm sonuçlarının karşılaştırılması ve merkezi kornea kalınlığı ile ilişkileri | en_US |
dc.title.alternative | Comparison of intraocular pressure measurements using four different tonometers and ıts relation with centrel corneal thickness in glaucoma patients | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- abdulgani-kaymaz.pdf
- Boyut:
- 172.25 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam metin/ Full text