THE EFFECT OF IMPLANT THERAPY ON MAXIMUM BITE FORCE IN EDENTULOUS ELDERLY PATIENTS: AN IN VIVO STUDY

dc.contributor.authorSener, Ismail
dc.contributor.authorAslan, M. Ali
dc.contributor.authorTek, Mustafa
dc.contributor.authorBereket, Cihan
dc.contributor.authorArici, Selim
dc.contributor.authorSato, Shuichi
dc.date.accessioned2024-09-25T19:57:37Z
dc.date.available2024-09-25T19:57:37Z
dc.date.issued2015
dc.departmentAbant İzzet Baysal Üniversitesien_US
dc.description.abstractIntroduction: The purpose of the present study was to compare the bite force differences between conventional complete denture prostheses and implant retained overdentures. Materials and Method: The study group consisted of 15 complete denture patients. Three months after insertion of conventional dentures, the first bite force measurements were made with a Dental Prescale sheet (Fuji Film, Tokyo). After 5 and 7 weeks, two implants were placed in the mandibular symphysis region. Three months after implant surgery, implant retained overdentures were fabricated. Three months after the insertion of implant retained overdentures, a second set of bite force measurements was made and the values were recorded. Bite forces were compared between conventional complete dentures and implant retained overdentures and the chewing satisfaction obtained from patients in both groups was measured using visual analogue scale. All results were evaluated statistically using a paired t-test and values of p<0.05 were considered as statistically significant. Results: Bite forces and chewing satisfaction increased in all patients after the implant retained overdenture insertion. The mean bite force values before and after implant therapy were found 194.03 +/- 95.08 Newton and 302.91 +/- 119.84 Newton respectively. According to the paired t-test, a statistically significant difference were found in bite forces and chewing satisfaction before and after implant therapy (p<0.05). Conclusions: The present study showed increased bite forces and chewing satisfaction after insertion of implant retained overdentures.en_US
dc.identifier.endpage80en_US
dc.identifier.issn1304-2947
dc.identifier.issn1307-9948
dc.identifier.issue1en_US
dc.identifier.startpage75en_US
dc.identifier.trdizinid194568en_US
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/194568
dc.identifier.urihttps://hdl.handle.net/20.500.12491/13499
dc.identifier.volume18en_US
dc.identifier.wosWOS:000352641100013en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakTR-Dizinen_US
dc.language.isoenen_US
dc.publisherGunes Kitabevi Ltd Stien_US
dc.relation.ispartofTurkish Journal of Geriatrics-Turk Geriatri Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.snmzYK_20240925en_US
dc.subjectDentureen_US
dc.subjectOverlayen_US
dc.subjectBite Forceen_US
dc.subjectDental Implantsen_US
dc.titleTHE EFFECT OF IMPLANT THERAPY ON MAXIMUM BITE FORCE IN EDENTULOUS ELDERLY PATIENTS: AN IN VIVO STUDYen_US
dc.typeArticleen_US