Mucus plugging problem in patients treated in the intensive care unit: A case report

Yükleniyor...
Küçük Resim

Tarih

2020

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

In this paper, we will present a case who died in ICU during treatment for suicidal organophosphate intoxication. It is aimed to draw attention to the importance of regular tracheal aspiration and bronchoscopy, especially in intubated patients during treatment in ICU. In the medical documents of the case, it was learned that a 67-year-old male case was brought to a private hospital with a history of suicidal Jestis 2.5 EC, Alban EC4 (organophosphate) intake. The case died after being treated in the ICU for a total of 15 days following organophosphate intake. At autopsy, during an internal examination, approximately 5x2x1,5 cm in size, with brown-black color, organized, hardened paste consistency mucus plug was observed which was localized in the bifurcation of the trachea. It is considered to be useful to evaluate the indication of bronchoscopy in cases with better general conditions and hope for recovery.

Açıklama

Anahtar Kelimeler

Mechanical Ventilator, Intubated Patients, Intensive Care Unit, Mucus Plug, Fiberoptic Bronchoscopy