Yazar "Yeğin, Elif" seçeneğine göre listele
Listeleniyor 1 - 6 / 6
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Comparison of radiopacity of current restorative CAD/CAM blocks with digital radiography(Wiley, 2019) Atala, Mustafa Hayati; Atala, Nagehan; Yeğin, Elif; Bayrak, SevalObjective While the radiopacity of restorative material affects the radiographic diagnosis of the teeth, there is no data about the radiopacity of current restorative computer-aided design (CAD)/computer-aided manufacturing (CAM) materials. Therefore, the present study compared the radiopacity values of current restorative CAD/CAM blocks to facilitate the material choice within such a wide variety of materials. Materials and Methods Specimens were prepared from 13 different restorative CAD/CAM blocks to compare with enamel and dentin. The specimens placed on the occlusal phosphor plate were imaged with aluminum step wedge and tooth section. The radiopacity values were calculated using the Image J program. The radiopacity values of the specimens were converted to mmAl values with the Curve Expert 1.4 program. Results The difference between the radiopacity values of dentin and e.max CAD was not significant, however, they exhibited a significant difference from the other 14 groups (P < .05). Enamel and Obsidien, Suprinity, and Celtra Duo had greater radiopacity values with significant differences from the other 12 materials whereas the difference within these groups was not significant (P > .05). Conclusions The evaluated restorative CAD/CAM materials have significantly different radiopacity values. Among these permanent restoration blocks, the highest radiopacity value was observed in Celtra Duo, the lowest in Block HC.Öğe Effect of different denture adhesives on retention of complete dentures: an in vivo study(Taylor & Francis Ltd, 2017) Yeğin, Elif; Akpınar, Yusuf Ziya; Yavuz, Tevfik; Aslan, Muhammed AliThe increase in prevalence of tooth loss with the effect of population aging produces the growing need for complete dentures. The success and acceptance of complete dentures by the patient depends on sufficient retention and stability. Therefore, denture adhesives are regularly used by denture wearers to improve the function of complete denture. We evaluated the effect of three different denture adhesives (Corega, Protefix, Fittydent) on the retention of maxillary complete denture (MCD) using with digital dynamometer (DD). For this purpose, denture adhesives were applied on MCDs of 30 participants. After chewing procedure, the force was applied at 45 degrees to the palatal surface of denture by DD. Dislodgement force was recorded by means of Newton. There were four measurements on each patient including; group of control: Group C; Group CR: Corega; Group F: Fittydent; Group P: Protefix. The result of the study was statistically evaluated by using analysis of variance (ANOVA) and Tukey HSD test. Statistics of ANOVA showed a significant difference among all the four groups (p=0.00, <0.05). Tukey HSD test indicated that there was a statistical difference between Group F and the other groups, but there was not a significant difference between the other groups. The highest adhesive strength value was observed in group F, the lowest in group C. Use of denture adhesives improved the retentive strength of complete denture.Öğe Effect of different mouthwashes on discoloration of plaque-free tooth surfaces(Mosher & Linder, Inc, 2018) Atala, Mustafa Hayati; Ustaoğlu, Gülbahar; Atala, Nagehan; Yeğin, ElifPurpose: To evaluate the tooth discoloration effect of the daily use protocol of six different mouthrinses. Methods: 70 extracted caries -free central incisors were divided into seven groups (n=10/per group): Group 1: Curasept Anti Discoloration System; Group 2: CB12; Group 3: Listerine Zero; Group 4: Listerine Cool Mint; Group 5: Colgate Plax; Group 6: Kloroben. The teeth were exposed to the mouthrinse for 2 minutes daily for 3 weeks. Color measurement was performed four times: at the beginning of the study, and after 1, 2 and 3 weeks, with a digital spectrophotometer (Vita Easyshade Advanced). Color changes (Delta E) were calculated and ANOVA and post hoc Tukey's test were used for statistical analysis. Results: Although there was no statistically significant difference between the Colgate Plax and control groups, both groups had a significant difference from the other groups within all Delta E1, Delta E2 and Delta E3 values.Öğe Effects of mouthrinses on discoloration of CAD-CAM manufactured restorative materials(Mosher & Linder, Inc, 2019) Atala, Mustafa Hayati; Yeğin, Elif; Atala, Nagehan; Şenlen, Esra; Bağlar, SerdarPurpose: To investigate the in vitro effect of four different mouthrinses on discoloration of popular CAD-CAM blocks. Methods: 40 specimens were prepared and then were divided into five groups (n = 8) for each CAD-CAM block (Vitablocks Mark II, IPS e-max CAD, GC LRF, Enamic, Cerasmart). In total, four different mouthrinses for each group (Listerine Zero, Parodontax, Kloroben, Oral B Pro-Expert) and distilled water for the control group were used. The specimens were immersed in 20 ml solution for 2 minutes, twice a day for 21 days with a 12-hour interval. Color changes were measured with a digital spectrophotometer (Vita Easyshade) after 7, 14 and 21 days and specimens were prepared. For statistical analysis, color changes (Delta E) were calculated and Kruskal Wallis and Wilcoxon tests were used. Results: There was not a significant difference in Delta E1 and Delta E2 values (P> 0.005) while there was a significant one in Delta E3 (P= 0.001) after Bonferroni correction for CAD-CAM materials were carried out as it is independent of the mouthrinse. Listerine Zero brought about the most noticeable color change in all CAD-CAM materials except e.Max after 21 days.Öğe İmplant üstü kronlarda CAD/CAM ile üretilen farklı materyallerin kırılma dayanımlarının ve implanta ilettiği kuvvetlerin değerlendirilmesi(Bolu Abant İzzet Baysal Üniversitesi, 2017) Yeğin, Elif; Atala, Mustafa HayatiGünümüzde diş eksikliklerinin tedavisinde implant destekli restorasyonlar sıklıkla tercih edilmektedir. Biyomekanik farklılıkların yol açtığı komplikasyonlar ve CAD/CAM teknolojisindeki gelişmelerin katkısıyla yaygınlaşan tam seramikler nedeniyle implant destekli restorasyonlarda kullanılan materyaller her zaman araştırmaların ilgi odağı olmuştur. Bu nedenle çalışmanın amacı, implant üstü kronlarda CAD/CAM ile üretilen farklı materyallerin kırılma dayanımlarını ve implant bileşenlerinde ve kemikte oluşturduğu stres dağılımlarını değerlendirmektir. Çalışmada kullanılan materyaller altı gruba ayrılmıştır: Grup L-M: Lityum disilikat seramik (Monolitik), Grup L-T: Lityum disilikat seramik (Konvansiyonel Tabakalama), Grup LZ-M: Zirkonya ile güçlendirilmiş lityum silikat seramik (Monolitik), Grup LZ-T: Zirkonya ile güçlendirilmiş lityum silikat seramik (Konvansiyonel Tabakalama), Grup CF: cad-on ile feldspatik seramikle veneerlenen zirkonya, Grup CL: cad-on ile lityum disilikat seramikle veneerlenen zirkonya. Kırılma dayanımı testi için tüm restorasyonlara 0.5 mm/dk hızında yük uygulandı. Her bir grubun kırılma dayanım değerleri istatistiksel olarak analiz edildi (ANOVA, Post Hoc Tukey HSD, ?=0.05). Grup L-M, Grup CL ve tüm diğer gruplar arasında istatistiksel olarak anlamlı fark bulunurken (p>0.05), Grup L-T, LZ-M, LZ-T ve CF arasında anlamlı fark bulunmadı (p<0.05). Grup CL en yüksek kırılma dayanımına (4649,22 ± 733,42 N) sahiptir ve onu sırasıyla L-M (2891,88 ± 410,12 N), LZ-T (2202,55 ± 503,14 N), CF (2085,91 ± 555,61 N), L-T (2077,37 ± 356,59 N), LZ-M (1750,28 ± 314,96 N) takip etmektedir. Kırılma dayanımı testi sonrası, fraktografik analiz kullanıldı ve komplikasyon açısından dayanak-implant kompleksleri kontrol edildi. FEA bulgularında, restoratif materyaller, implant bileşenleri üzerindeki stres dağılımını etkilemezken, monolitik restorasyonlarda implant ve kemikte daha az stres birikimi belirlendi.Öğe Sınıf 5 kavitelerde restoratif materyal seçimi(2015) Yeğin, Elif; Akpınar, Yusuf Ziya; Topbaşı, Bülent; Yılmaz, PınarAmaç: Bu çalışmanın amacı, yeni nesil self adeziv akışkan kompozit, kompomer ve nanohibrid kompozit ile restore edilen Sınıf 5 restorasyonların mikrosızıntı değerlerini karşılaştırmaktır. Gereç ve Yöntemler: Otuz adet üst santral dişin bukkal yüzeyinde standardize Sınıf 5 kavite (2x4x1.5mm) hazırlandı. Dişler rastgele üç gruba ayrıldı (n=10): Group DEC: DyractExtra Kompomer; Group EWB: Embrace WetBond Akışkan Kompozit; Group NHC: Nano-hibrid Kompozit Grandio. Bitirme ve cila işleminden sonra dişler 37°C'de distile suda 4 hafta bekletildi, %0,5 bazik fuksine batırıldı ve sonrasında aksiyel kesitler alındı. Boya penetrasyonu stereomikroskopta (X50) incelendi. Mikrosızıntı değerleri µm cinsinden hesaplandı. Bulgular: Grupların mikrosızıntı değerleri arasındaki farklılık istatistiksel olarak anlamlı bulundu (p=0.046). En yüksek mikrosızıntı değeri Grup DEC'de (550 ± 250 µm) gözlenirken, en düşük değer Grup EWB'da (260 ± 130 µm) gözlemlendi. Sonuç: Restoratif materyallerin hiçbiri mikrosızıntıyı elimine edememiştir. Sınıf 5 kavitelerin yeni nesil self adeziv akışkan kompozitler ile restore edilmesi mikrosızıntıyı azaltmaktadır.