In this paper a comparison study was carried out in order to understand how two different systems, classical and fuzzy logic control of central heating affect the economy and comfort of private homes or offices. Also a literature review was done to help decide which one of these systems is more effective. The objective of the fuzzy controller heating system is to estimate the actual heat requirement of the house. It uses a total of five inputs, four of which are derived from energy consumption curve, using conventional digital filtering techniques; the fifth is the average outdoor temperature, whereas, the classical control system burns diesel type fuel in its furnace to heat the water supply (boiler). From the boiler, the hot water is distributed by a pipe system to the individual radiators in the house. Thereby, it is shown that the fuzzy controlled heating system is more effective, also it maximizes the economy and the comfort of the consumer. © 2002 John Wiley and Sons, Ltd.