Yazar "Toprak, Güvenç" seçeneğine göre listele
Listeleniyor 1 - 6 / 6
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Comparison of the short-term effect of coffee, energy drink, and water on the eyes in young healthy subjects(Springernature, 2023) Toprak, Güvenç; Alkan, YunusPurpose: We aim to compare the short-term effects of energy drink (ED), coffee, and water on the eyes of young healthy male subjects.Materials and methods: The right eyes of 30 healthy male subjects were included in this study. We measured the intraocular pressure (IOP), mean arterial pressure (MAP), retinal thickness (RT), choroidal thickness (CT), and retinal nerve fiber layer (RNFL) thickness using spectral domain optical coherence tomography (SD OCT). The measurements for RT and CT were taken at the fovea as well as 1,500 mu m nasal and temporal to the fovea. The measurements of the subjects were performed on the first day before water consumption and at 30 minutes and 60 minutes following intake of 250 mL of water. Measurements were repeated at the same regime on the second day after drinking 250 mL of coffee containing an equal concentration of caffeine in ED (37.5 mg) and on the third day after drinking 250 mL of ED. Repeated measures one-way analysis of variance test was used for statistical analysis.Results: No significant difference was found for ocular perfusion pressure (OPP), MAP, RT, and IOP between the measurements taken on three consecutive days (p>0.05 for all). The CT values for the central, nasal, and temporal segments were significantly reduced in 0-30 and 0-60 minutes following coffee and ED intake (the range of p-value was <0.001-0.027).Conclusions: Both coffee and ED intake caused acute and significant decreases in CT that persisted for one hour in young healthy male subjects. The impact of ED intake on CT was attributed mainly to its caffeine content.Öğe Diyabetik retinopati ve yaş tip yaşa bağlı makula dejenerasyonu hastalarında tekrarlayan intravitreal aflibercept ve ranibizumab uygulamasının göz içi basınç değişimi üzerine etkilerinin değerlendirilmesi(Bolu Abant İzzet Baysal Üniversitesi, 2019) Toprak, Güvenç; Çelebi, SerdalGüvenç TOPRAK, Diyabetik Retinopati ve Yaş Tip Yaşa Bağlı Makula Dejenerasyonu Hastalarında Tekrarlayan İntravitreal Aflibercept ve Ranibizumab Uygulamasının Göz İçi Basınç Değişimi Üzerine Etkilerinin Değerlendirilmesi. Uzmanlık Tezi, Bolu, 2019 Yaşa bağlı makula dejenerasyonu gelişmiş ülkelerde ileri yaşta geri dönüşümsüz görme kaybının en sık nedenidir. Yaş tip ve kuru tip olmak üzere iki tipi mevcuttur. Yaş tipi daha az görülmesine rağmen kuru tipine göre daha agresif seyretmektedir. Yaş tip yaşa bağlı makula dejenerasyonunda karakteristik lezyon koroidal neovasküler membran oluşumudur. Koroidal neovasküler membran oluşumundan ise Vasküler Endotelyal Growth Faktör (VEGF) sorumlu tutulmaktadır. Diyabetik retinopati (DRP) 20-65 yaş arasında önlenebilir körlüğün en sık nedenlerindendir. Diyabetik retinopatide görme kaybı en sık diyabetik maküler ödeme bağlı gelişmektedir. Diyabetik maküler ödem ise, vasküler geçirgenlikte artışa bağlı olarak gelişmektedir. Bu durumun artan VEGF yükü ile ilişkili olduğu bilinmektedir. Her iki hastalığın ortak patogenezinde VEGF yer almaktadır ve tedavilerinde Ranibizumab ya da Aflibercept gibi anti-VEGF ajanlar kullanılmaktadır. Anti-VEGF ajanlar intravitreal uygulanır ve enjeksiyon sonrasında göz içi basınç artışı ve vitreus reflüsü sık gelişen iki durumdur. Çalışmamızdaki amacımız tekrarlayan sayıda intravitreal enjeksiyon uygulanan hastalarda enjeksiyon sonrasında göz içi basınç değişimi ve vitreus reflüsü sıklığı üzerine hastalığın tipinin, uygulanan enjeksiyonun türünün ve sayısının etkilerini araştırmaktır. Çalışmada DRP ve YBMD nedeniyle intravitreal enjeksiyon tedavisi alan 160 göz değerlendirildi. Hasta grupları en az 10 anti-VEGF tedavisi almış hastalardan oluşmakta idi. Her iki grupta toplam 24 açık açılı glokom tanısı ile takipli hasta mevcuttu. Hastalara Aflibercept ya da Ranibizumab tedavisi uygulandı. Çalışmada hastaların demografik ve klinik bilgileri, toplam Aflibecept ve Ranibizumab sayıları, toplam DRP ve YBMD hasta sayıları, enjeksiyon öncesi, sonrası ve 30 dakika sonrasında göz içi basınç değerleri, enjeksiyon sonrasında vitreus reflüsüne bağlı gelişen konjonktival bleb çapı değerleri, lens durumu, psödoeksfoliasyon durumu ve glokomlu hastaların enjeksiyondan önceki ve enjeksiyondan sonraki 6. Ayda RNFL değerleri gibi parametreler değerlendirildi. DRP ve YBMD hasta gruplarının toplam enjeksiyon sayıları, intravitreal enjeksiyon öncesi ve enjeksiyondan 30 dk. sonraki göz içi basınç değerleri arasında istatistiksel olarak anlamlı fark saptanmadı. YBMD hasta grubunda enjeksiyondan sonraki erken dönem GİB değerleri istatistiksel anlamlı olarak daha düşük saptandı. Her iki grubun yaş ortalamaları arasında istatistiksel olarak anlamlı fark saptandı. YBMD hastalarında yaş ortalamasının daha yüksek olduğu gözlendi. Her iki grup arasında vitreus reflüsüne bağlı konjonktival bleb çapları arasında istatistiksel olarak anlamlı fark saptandı ve YBMD hastalarında daha yüksek olduğu gözlendi. Her iki grupta da enjeksiyondan önceki ve enjeksiyondan sonraki açık açılı glokom tanısı ile takipli hastaların RNFL değerlerinde incelme olduğu saptandı. Bu incelmenin DRP hasta grubunda istatistiksel anlamlı olarak daha fazla olduğu gözlendi. Aflibercept ve Ranibizumab hasta gruplarında da aynı parametreler değerlendirilmiş olup, gruplar arasında göz içi basınç değerleri ve vitreus reflüsüne bağlı konjonktival bleb çapı değerleri arasında istatistiksel olarak anlamlı bir fark saptanmadı. Tüm hasta gruplarında vitreus reflüsüne bağlı konjonktival bleb çapı ile erken dönem göz içi basınç değerleri arasında ters yönlü istatistiksek olarak anlamlı korelasyon olduğu gözlendi. Tüm hasta gruplarında hastaların psödofakik olması ile enjeksiyon sonrasında erken dönemde göz içi basınç artışı arasında istatistiksel olarak anlamlı ilişki olduğu gözlendi. Tüm gruplarda enjeksiyon sayısı ile göz içi basınç değerleri arasındaki ilişkiye bakıldı ve istatistiksel olarak anlamlı bir ilişki olmadığı gözlendi. Sonuç olarak; yaş tip YBMD hastalarında, DRP hastalarına oranla intravitreal enjeksiyon sonrasında vitreus reflüsüne bağlı konjonktival bleb çapı değerleri istatistiksel olarak daha büyük ölçülmüş olup, bu durumun yaşla artan vitreus likefaksiyonuna bağlı olabileceği düşünüldü. Bu durumun da YBMD hasta gurubunda enjeksiyon sonrasındaki erken dönem GİB değerlerinin daha düşük saptanmasına neden olabileceği düşünüldü. Ayrıca glokomlu DRP hasta grubunda RNFL incelmesinin intravitreal enjeksiyon sonrasındaki GİB yükselmesine bağlı olabileceği düşünüldü. Bu hasarın glokomlu genç bireylerde daha fazla olabileceği öngörülerek, bu hastalara intravitreal enjeksiyon öncesi premedikasyon önerilebileceği düşünüldü. Psödofakik hastalarda enjeksiyon sonrası erken dönem göz içi basınç artışı daha az görüldü. Geçirilmiş katarakt cerrahisi sonrasında artmış vitreus boşluğu hacminin enjeksiyon sonrası daha az göz içi basınç artışına neden olabileceği düşünüldü. Anahtar Kelimeler: Diyabetik retinopati, Yaş tip yaşa bağlı makula dejenerasyonu, Aflibercept, Ranibizumab, Göz içi basıcı, Vitreus reflüsü, RNFLÖğe Evaluation and comparison of optical coherence tomography angiography (OCTA) parameters in normal and moderate myopic individuals(Elsevier, 2024) Toprak, Güvenç; Ulaş, Fatih; Kaymaz, Abdulgani; Soydan, Adem; Kaplan, Abdulfatih; Alkan, Yunus; Özdemir, Buse; Bayrak, AbdullahObjective: The objective of this study was to evaluate and compare Optical Coherence Tomography Angiography (OCTA) parameters in patients with moderate myopia and healthy individuals retrospectively. Methods: A total of 80 male individuals aged 18-20 years were included in the study with 40 moderate myopic and 40 healthy persons. All participants underwent detailed ocular examination including refraction, intraocular pressure (IOP), visual acuity, biomicroscopy, OCTA measurement and optic biometry measurement. Retinal, retinal nerve fiber layer and choroidal layer thicknesses were evaluated in mu m with the help of the software available in the OCTA device. Results: The mean axial length (24.32 +/- 0.53 mm) was statistically significantly higher in the moderate myopic group (24.32 mm) compared to the healthy group (23.33 +/- 0.61 mm) (p < 0.001). Spherical equivalent (SE) was found as -3.79 +/- 0.91 D in the moderate myopic group and -0.22 +/- 0.32 D in the healthy group (p < 0.05). The mean superficial foveal mean density (FovSupMVD) and the mean deep foveal mean density (FovDepMVD) were statistically significantly lower in the moderate myopic group than in the healthy group (both, p < 0.001). The mean retinal temporal thickness (RTt) was statistically significantly lower in the moderate myopic group (p = 0.017). There was a mild negative correlation between axial length and FovSupMVD, FovDepMVD in myopes. In axial length ROC analysis, the cutoff value for moderate myopes was found to be 24.15 mm. Mean superficial foveal mean density (FovSupMVD) and mean deep foveal mean density (FovDepMVD), mean retinal temporal thickness (RTt) were significantly lower in the group above 24.15 mm axial length compared to the group below 24.15 mm axial length (all three, p < 0.001). Foveal avascular zone was significantly higher in the group above 24.15 mm axial length (p = 0.016) Conclusion: The results of our study indicate that the mean axial length and spherical equivalent were significantly higher, while retinal temporal thickness, the mean superficial foveal mean density and the mean deep foveal mean density were significantly lower in patients with myopia up to -6.0 D compared to the healthy individuals.Öğe Evaluation of the acute effects of cigarette smoking on the eye of non-Smoking healthy young male subjects by optical coherence tomography angiography(Taylor & Francis Ltd, 2020) Kaymaz, Abdulgani; Ulaş, Fatih; Toprak, Güvenç; Uyar, Enes; Çelebi, SerdalPurpose: Investigation of the acute effects of cigarette smoking on the eye using optical coherence tomography angiography (OCTA) on young healthy non-smoking male subjects. Materials and methods: The right eye of 25 healthy non-smoking male subjects were included in this study. Selected parameters of the macular and circumpapillary vasculature were measured, including macular flow indices, foveal avascular zone, vessel densities of macula and optic disc using OCTA. The measurements of the subjects were performed on the first day without smoking at 0 min, 5 min, 30 min and 60 min. Measurements were repeated at the same regime on the second day after smoking. Paired samples t-test and repeated measures one-way analysis of variance test was used for the statistical analysis. Results: The repeated measures analysis of variance test using the Bonferroni adjustment demonstrated a significant change for superficial and deep foveal vessel density, flow area of choriocapillaris, and circumpapillary capillary density following smoking (range of p value was <0.001-0.004). Intraocular pressure, foveal avascular zone area, flow area of outer retina and foveal non-flow area of superficial layer measurements did not have any significant changes following smoking (range of p value was 0.192-0.812). Conclusion: In non-smoking cases, even smoking only one cigarette significantly decreased the vessel density parameters at the acute period. Even though there was an increase in measured parameters shortly after smoking, it had lessened when compared to non-smokers, even one hour following smoking.Öğe Investigation of the short-term effects of water drinking test on the eye using optical coherence tomography angiography in young healthy male subjects(Taylor & Francis Ltd, 2022) Soydan, Adem; Ulaş, Fatih; Kaymaz, Abdulgani; Toprak, Güvenç; Uyar, Enes; Çelebi, SerdalPurpose To evaluate the acute effects of the water drinking test (WDT) on the eye using optical coherence tomography angiography (OCTA) on healthy young male subjects. Methods The study included 25 eyes of 25 male subjects. Selected parameters of the retinal vasculature were measured, including macular flow indices, foveal avascular zone, and vessel densities (VDs) of the macula using OCTA. The measurements were taken on the first day without drinking water at 0 min, 30 min and 60 min, then repeated on the second day before drinking water at 0 min, and after drinking water at 30 min and 60 min. The Paired Samples t-test and repeated measures One-way analysis of variance test were used in the statistical analyses. Results The repeated measures analysis of variance test using Bonferroni adjustment demonstrated a significant increase in superficial and deep foveal VD following WDT (p < 0.001 for both). Intraocular pressure, retinal nerve fibre layer thickness, foveal avascular zone, flow area of choriocapillaris, flow area of outer retina, foveal non-flow area of superficial layer, and retinal thickness measurements showed no significant changes following WDT. Conclusions WDT is associated with temporary flow modifications in superficial and deep foveal vascular plexus in young male subjects.Öğe Preoperative evaluation of white cataracts with the pentacam(Elsevier, 2024) Toprak, Güvenç; Alkan, Yunus; Bayrak, AbdullahPurpose: To evaluate the use of the Pentacam to analyse the presence or absence of fluid pockets under the anterior capsule and their significance in terms of surgical management and prevention of complications. Settings: Abant & Idot;zzet Baysal University Hospital, Bolu, Turkey DESIGN: Randomized, masked, prospective design METHODS: 60 patients with mature cataracts underwent standard phacoemulsification (Phaco) and intraocular lens (IOL) implantation. Patients were divided into 3 groups. Group 1 underwent Phaco+IOL implantation without imaging by Pentacam. Group 2 had fluid detected in Pentacam imaging before the operation and underwent Phaco+IOL implantation with Brazilian method. Group 3 had no fluid detected in Pentacam imaging before the operation and underwent standart Phaco+IOL implantation operation. Results: When the complication rates of 3 different groups were examined separately, they were found to be 15 % in group 1; 5 % in group 2 and 5 % in group 3, respectively. When compared in pairs as Group 1-2, 1-3, and 2-3, respectively (p < 0.01), (p < 0.01), (p > 0.05). The nuclear density of Group 2 and Group 3 was measured, resulting in 30.2 % and 29.6 %, respectively (P = 0.614). Lens thickness, patients with fluid (+) had a thickness of 5.35 mm, while patients with fluid (-) had a thickness of 3.96 mm (p < 0.05). Conclusion: Patients who are not imaged with pentacam before surgery experience more complications than other groups because the presence of fluid is unknown. Central lens thickness was higher in patients with fluid, and there was no significant difference in nuclear density between the groups with and without fluid. Pentacam can show the presence of supcapsular fluid and we recommend that imaging tools be more widely used in cataract surgery. We think that this will enable surgeons to make a more accurate surgical planning and reduce the risk of complications.